STATIC AND DYNAMIC TESTS OF TIMBER SHEAR WALLS FASTENED WITH NAILS AND WOOD ADHESIVE

被引:11
作者
FILIATRAULT, A [1 ]
FOSCHI, RO [1 ]
机构
[1] UNIV BRITISH COLUMBIA,DEPT CIVIL ENGN,VANCOUVER V6T 1W5,BC,CANADA
关键词
ADHESIVE; EARTHQUAKE; TESTS; TIMBER CONSTRUCTION; SHEAR WALLS; WOOD;
D O I
10.1139/l91-091
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation into the seismic behaviour of timber shear walls fastened with nails alone or with nails in combination with wood adhesive. The responses of both types of shear walls were determined under slow, quasi-static racking loads and also under dynamic, earthquake-induced conditions. The experimental results showed that the introduction of the adhesive makes shear walls much stronger but also more brittle than conventional nailed walls. It was observed that shear walls incorporating nails and adhesive behaved almost linearly to failure. To obtain the most out of the adhesive capacity, however, the wood framing should be designed with special attention to the connections between framing members and the anchoring of the wall's base plate. These details control the capacity of the frame to sustain the loads induced by the stiffer adhesive joints.
引用
收藏
页码:749 / 755
页数:7
相关论文
共 6 条
[1]  
ASTENSH A, 1989, UCBEERC8914 U CAL EA
[2]  
Dolan JD, 1989, THESIS U BRIT COLUMB, DOI 10.14288/1.0062552
[3]   STATIC AND DYNAMIC ANALYSIS OF TIMBER SHEAR WALLS [J].
FILIATRAULT, A .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1990, 17 (04) :643-651
[4]  
NEWMARK NM, 1987, EARTHQUAKE ENG RES I
[5]  
1987, ANN BOOK ASTM STANDA
[6]  
1987, WOOD ADHESIVE 5230 T