MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW WITH POSITRON EMISSION TOMOGRAPHY - A COMPARISON OF [O-15]WATER TO [C-11] BUTANOL WITH DISTRIBUTED-PARAMETER AND COMPARTMENTAL-MODELS

被引:36
|
作者
QUARLES, RP
MINTUN, MA
LARSON, KB
MARKHAM, J
MACLEOD, AM
RAICHLE, ME
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DIV RADIAT SCI,510 S KINGSHIGHWAY,ST LOUIS,MO 63110
[2] UNIV FLORIDA,DEPT RADIOL,GAINESVILLE,FL 32611
[3] UNIV PITTSBURGH,DIV NUCL MED,PITTSBURGH,PA 15260
[4] WASHINGTON UNIV,DEPT NEUROL & NEUROSURG,ST LOUIS,MO 63130
[5] WASHINGTON UNIV,INST BIOMED COMP,ST LOUIS,MO 63130
来源
关键词
BLOOD FLOW TRACERS; BRAIN ACTIVATION; COMPARTMENTAL MODELS; DISPERSION AND DELAY; DISTRIBUTED-PARAMETER MODELS; POSITRON EMISSION TOMOGRAPHY; REGIONAL CEREBRAL BLOOD FLOW;
D O I
10.1038/jcbfm.1993.94
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To further our understanding of the best way to measure regional CBF with positron emission tomography (PET), we directly compared two candidate tracers ([O-15]water and [C-11]butanol, administered intravenously) and two popular implementations of the one-compartment (1C) model: the autoradiographic implementation representing a single PET measurement of tissue radioactivity over 1 min and a dynamic implementation representing a sequence of measurements of tissue radioactivity over 200 s. We also examined the feasibility of implementing a more realistic, and thus more complex, distributed-parameter (DP) model by assigning fixed values for all of its parameters other than CBF and tracer volume of distribution (Vd), a requirement imposed by the low temporal resolution and statistical quality of PET data. The studies were performed in three normal adult human subjects during paired rest and visual stimulation. In each subject seven regions of interest (ROIs) were selected, one of which was the primary visual cortex. The corresponding ROI were anatomically equivalent in the three subjects. Regional CBF, V(d), tracer arrival delay, and dispersion were estimated for the dynamic data curves. A total of 252 parameter sets were estimated. With [C-11]butanol both implementations of the 1C model provided similar results (r = 0.97). Flows estimated using the 1C models were lower (p < 0.01) with [O-15]water than with [C-11]butanol. In comparison with the 1C model, the constrained version of the DP used in these studies performed inadequately, overestimating high flow and underestimating low flow with both tracers, possibly as the result of the necessity of assigning fixed values for all of its parameters other than CBF and V(d).
引用
收藏
页码:733 / 747
页数:15
相关论文
共 50 条
  • [41] WATER DIFFUSION AND MEASUREMENT OF CEREBRAL BLOOD-FLOW BY (CO2)-O-15 INHALATION
    STEINLING, M
    BARON, JC
    SOUSSALINE, F
    ROUSSEAU, J
    COMAR, D
    NAQUET, R
    KELLERSHOHN, C
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1983, 10 (01): : 17 - 22
  • [42] DISSOCIATION OF OBJECT AND SPATIAL VISION IN HUMAN EXTRASTRIATE CORTEX - AGE-RELATED-CHANGES IN ACTIVATION OF REGIONAL CEREBRAL BLOOD-FLOW MEASURED WITH [O-15]WATER AND POSITRON EMISSION TOMOGRAPHY
    GRADY, CL
    HAXBY, JV
    HORWITZ, B
    SCHAPIRO, MB
    RAPOPORT, SI
    UNGERLEIDER, LG
    MISHKIN, M
    CARSON, RE
    HERSCOVITCH, P
    JOURNAL OF COGNITIVE NEUROSCIENCE, 1992, 4 (01) : 23 - 34
  • [43] COMPARISON OF CEREBRAL BLOOD-FLOW RESULTS USING (I-123) IODOAMPHETAMINE SINGLE-PHOTON TOMOGRAPHY AND (O-15)-H2O POSITRON EMISSION TOMOGRAPHY
    KUSHNER, MJ
    GREENBERG, J
    REIVICH, M
    ABASS, A
    CHANG, W
    RANGO, M
    CALCANOPEREZ, J
    ANNALS OF NEUROLOGY, 1988, 24 (01) : 123 - 124
  • [44] Interdependence of regional and global cerebral blood flow during visual stimulation: An O-15-butanol positron emission tomography study
    Kemna, LJ
    Posse, S
    Tellmann, L
    Schmitz, T
    Herzog, H
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2001, 21 (06): : 664 - 670
  • [45] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW DURING VOLITIONAL BREATHING USING POSITRON EMISSION TOMOGRAPHY IN MAN
    COLEBATCH, JG
    ADAMS, L
    MURPHY, K
    MARTIN, AJ
    LAMMERTSMA, AA
    TOCHONDANGUY, HJ
    CLARK, JC
    FRISTON, KJ
    GUZ, A
    JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P24 - P24
  • [46] ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION
    IIDA, H
    KANNO, I
    MIURA, S
    MURAKAMI, M
    TAKAHASHI, K
    UEMURA, K
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05): : 536 - 545
  • [47] QUANTITATIVE MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW IN HUMANS BY POSITRON COMPUTED-TOMOGRAPHY AND O-15-WATER
    HUANG, SC
    CARSON, RE
    HOFFMAN, EJ
    CARSON, J
    MACDONALD, N
    BARRIO, JR
    PHELPS, ME
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1983, 3 (02): : 141 - 153
  • [48] EVALUATION OF REGIONAL CEREBRAL BLOOD-FLOW AND VOLUME OF RAPIDLY EXCHANGEABLE WATER IN MAN BY POSITRON EMISSION TOMOGRAPHY
    DEPRESSEUX, JC
    CHESLET, JP
    HODIAUMONT, J
    JOURNAL DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1982, 6 (04): : 173 - 177
  • [49] MYOCARDIAL BLOOD-FLOW AND METABOLISM IN PATIENTS WITH HYPERTROPHIC CARDIOMYOPATHY - A STUDY WITH C-11 ACETATE AND POSITRON EMISSION TOMOGRAPHY
    ISHIWATA, S
    MARUNO, H
    SENDA, M
    TOYAMA, H
    ISHIWATA, K
    NISHIYAMA, S
    SEKI, A
    CIRCULATION, 1993, 88 (04) : 172 - 172
  • [50] ALTERNATING HEMIPLEGIA IN INFANCY - 2 CASE-REPORTS AND REDUCED REGIONAL CEREBRAL BLOOD-FLOW IN (CO2)-C-11 DYNAMIC POSITRON EMISSION TOMOGRAPHY
    SAKURAGAWA, V
    MATSUO, T
    KIHIRA, S
    MATSUZAKA, T
    MATSUI, A
    ARIMA, M
    NITTA, H
    BRAIN & DEVELOPMENT, 1985, 7 (02): : 207 - 207