STOPPED-FLOW X-RAY ABSORPTION SPECTROSCOPY IN DISPERSIVE MODE

被引:11
作者
Saigo, S. [1 ]
Oyanagi, H. [2 ]
Matsushita, T. [3 ]
Hashimoto, H. [4 ]
Yoshida, N. [5 ]
Fujimoto, M. [5 ]
Nagamura, T. [6 ]
机构
[1] Jichi Med Sch, Dept Phys, Minami Kawachi, Tochigi 32904, Japan
[2] Electrotech Lab, Sakura, Ibaraki 305, Japan
[3] Natl Lab High Energy Phys, Photon Factory, Oho, Ibaraki 305, Japan
[4] Toray Res Ctr, Otsu, Shiga 520, Japan
[5] Hokkaido Univ, Fac Sci, Dept Chem 2, Sapporo, Hokkaido 060, Japan
[6] Unisoku Inc, Hirakata, Osaka 57301, Japan
来源
JOURNAL DE PHYSIQUE | 1986年 / 47卷 / C-8期
关键词
D O I
10.1051/jphyscol:19868104
中图分类号
学科分类号
摘要
A new stopped-flow device particularly suitable for X-ray absorption spectroscopy in dispersive mode has been built. Time-resolved measurements of X-ray absorption spectra have been made for reactions in mixed solutions of (i) iron(III) nitrate and catechol and (ii) iron(III) nitrate and sodium thiosulfate with time resolutions of similar to 5 ms to a few seconds. Two-step variation of the spectra was observed for the former reaction, while one-step variation for the latter.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 11 条
[1]   X-RAY ABSORPTION IN DISPERSIVE MODE - A NEW SPECTROMETER AND A DATA ACQUISITION-SYSTEM FOR FAST KINETICS [J].
DARTYGE, E ;
DEPAUTEX, C ;
DUBUISSON, JM ;
FONTAINE, A ;
JUCHA, A ;
LEBOUCHER, P ;
TOURILLON, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :452-460
[2]   EXAFS IN DISPERSIVE MODE [J].
FLANK, AM ;
FONTAINE, A ;
JUCHA, A ;
LEMONNIER, M ;
RAOUX, D ;
WILLIAMS, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3) :651-654
[3]  
Fontaine A., 1984, EXAFS NEAR EDGE STRU, P403
[4]   STOPPED-FLOW SOLUTION SCATTERING USING SYNCHROTRON RADIATION - APPARATUS, DATA-COLLECTION AND DATA-ANALYSIS [J].
FOWLER, AG ;
FOOTE, AM ;
MOODY, MF ;
VACHETTE, P ;
PROVENCHER, SW ;
GABRIEL, A ;
BORDAS, J ;
KOCH, MHJ .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1983, 7 (04) :317-329
[5]   Cinetics and reaction mechanism of ferric salt reduction using thiosulfate in weak acid solutions [J].
Holluta, J ;
Martini, A .
ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 1924, 140 (1/2) :206-226
[6]   25 MILLISECOND RESOLUTION TIME-RESOLVED X-RAY ABSORPTION-SPECTROSCOPY IN DISPERSIVE MODE [J].
MATSUSHITA, T ;
OYANAGI, H ;
SAIGO, S ;
KAMINAGA, U ;
HASHIMOTO, H ;
KIHARA, H ;
YOSHIDA, N ;
FUJIMOTO, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1986, 25 (07) :L523-L525
[7]   A FAST X-RAY ABSORPTION SPECTROMETER FOR USE WITH SYNCHROTRON RADIATION [J].
MATSUSHITA, T ;
PHIZACKERLEY, RP .
JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (11) :2223-2228
[8]  
Matsushita T., 1984, EXAFS NEAR EDGE STRU, P476
[9]   STOPPED-FLOW X-RAY-SCATTERING DEVICE WITH A SLIT-TYPE MIXER [J].
NAGAMURA, T ;
KURITA, K ;
TOKIKURA, E ;
KIHARA, H .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1985, 11 (4-5) :277-286
[10]   AN ENERGY-DISPERSIVE SPECTROMETER FOR THE RAPID MEASUREMENT OF X-RAY ABSORPTION-SPECTRA USING SYNCHROTRON RADIATION [J].
PHIZACKERLEY, RP ;
REK, ZU ;
STEPHENSON, GB ;
CONRADSON, SD ;
HODGSON, KO ;
MATSUSHITA, T ;
OYANAGI, H .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1983, 16 (APR) :220-232