A review of the firing behavior of pyrometric products is given with emphasis on how cone bending positions can be measured with a template and then used to provide data for a statistical process control (SPC) program. The angular degree the cone bends can be directly related to temperature and the heatwork the cone experienced during firing. Using nomographs and tables prepared by Orton, temperature variations at different locations can be determined.