CONTINUOUS DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENT (FINAPRES) IN THE CRITICALLY ILL

被引:20
作者
FARQUHAR, IK [1 ]
机构
[1] UNIV NOTTINGHAM HOSP, DEPT ANAESTHESIA, NOTTINGHAM NG7 2UH, ENGLAND
关键词
MEASUREMENT TECHNIQUES; PLETHYSMOGRAPHY; EQUIPMENT; FINAPRES;
D O I
10.1111/j.1365-2044.1991.tb09922.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Continuous noninvasive blood pressure measurement is of great potential use in the critically ill. This study was designed to find out whether measurements of blood pressure by a Finapres accurately represented intra‐arterial pressure. Comparisons were made between readings from a radial artery line and from a Finapres finger cuff in 10 critically ill patients. There was an unpredictable but usually stable difference between measurements from the two sources; this difference varied in magnitude and direction in individual patients. A t present the Finapres cannot be recommended as a substitute for intra‐arterial blood pressure measurement in the critically ill. Copyright © 1991, Wiley Blackwell. All rights reserved
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE BLOOD-PRESSURE IN THE FINGER, MEASURED CONTINUOUSLY BY A NEW NONINVASIVE METHOD (THE FINAPRES) [J].
DORLAS, JC ;
NIJBOER, JA ;
BUTIJN, WT ;
VANDERHOEVEN, GMA ;
SETTELS, JJ ;
WESSELING, KH .
ANESTHESIOLOGY, 1985, 62 (03) :342-345
[3]  
EAST T D, 1987, Anesthesiology (Hagerstown), V67, pA186, DOI 10.1097/00000542-198709001-00186
[4]  
Folkow B., 1971, CIRCULATION
[5]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[6]  
GEDDES LA, 1970, DIRECT INDIRECT MEAS
[7]   COMPARISON OF FINAPRES NONINVASIVE BEAT-TO-BEAT FINGER BLOOD-PRESSURE WITH INTRABRACHIAL ARTERY PRESSURE DURING AND AFTER BICYCLE ERGOMETRY [J].
IDEMA, RN ;
VANDENMEIRACKER, AH ;
IMHOLZ, BPM ;
TVELD, AJMI ;
SETTELS, JJ ;
VANECK, HJR ;
SCHALEKAMP, MADH .
JOURNAL OF HYPERTENSION, 1989, 7 :S58-S59
[8]   CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER [J].
IMHOLZ, BPM ;
VANMONTFRANS, GA ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1988, 22 (06) :390-397
[9]   NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE [J].
IMHOLZ, BPM ;
SETTELS, JJ ;
VANDERMEIRACKER, AH ;
WESSELING, KH ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1990, 24 (03) :214-221
[10]   COMPARISON OF THE FINAPRES BLOOD-PRESSURE MONITOR WITH INTRA-ARTERIAL MANOMETRY DURING INDUCTION OF ANESTHESIA [J].
KERMODE, JL ;
DAVIS, NJ ;
THOMPSON, WR .
ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) :470-475