Streamlined open-source gel dosimetry analysis in 3D slicer

被引:9
作者
Alexander, K. M. [1 ]
Pinter, C. [2 ]
Fichtinger, G. [2 ]
Olding, T. [1 ,3 ,4 ]
Schreiner, L. J. [1 ,3 ,4 ]
机构
[1] Queens Univ, Dept Phys, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Sch Comp, Kingston, ON K7L 3N6, Canada
[3] Kingston Gen Hosp, Canc Ctr Southeastern Ontario, 25 King St West, Kingston, ON K7L 5P9, Canada
[4] Queens Univ, Dept Oncol, Kingston, ON K7L 3N6, Canada
关键词
radiation therapy; 3d dosimetry; gel dosimetry;
D O I
10.1088/2057-1976/aad0cf
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three dimensional dosimetry is being used in an increasingly wide variety of clinical applications as more gel and radiochromic plastic dosimeters become available. However, accessible 3D dosimetry analysis tools have not kept pace. 3D dosimetry data analysis is time consuming and laborious, creating a barrier to entry for busy clinical environments. To help in the adoption of 3D dosimetry, we have produced a streamlined, open-source dosimetry analysis system by developing a custom extension in 3D Slicer, called the Gel Dosimetry Analysis slicelet, which enables rapid and accurate data analysis. To assist those interested in adopting 3D dosimetry in their clinic or those unfamiliar with what is involved in a 3D dosimeter experiment, we first present the workflow of a typical gel dosimetry experiment. This is followed by the results of experiments used to validate, step-wise, each component of our software. Overall, our software has made a full 3D gel dosimeter analysis roughly 20 times faster than previous analysis systems.
引用
收藏
页数:14
相关论文
共 41 条
[31]   Characterization of a commercially-produced chemically stable Fricke gel dosimeter [J].
Penev, K. I. ;
Mequanint, K. .
8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
[32]   Performing radiation therapy research using the open-source SlicerRT toolkit [J].
Pinter, Csaba ;
Lasso, Andras ;
Wang, An ;
Sharp, Gregory C. ;
Alexander, Kevin ;
Jaffray, David ;
Fichtinger, Gabor .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 :622-625
[33]   SlicerRT: Radiation therapy research toolkit for 3D Slicer [J].
Pinter, Csaba ;
Lasso, Andras ;
Wang, An ;
Jaffray, David ;
Fichtinger, Gabor .
MEDICAL PHYSICS, 2012, 39 (10) :6332-6338
[34]  
Poulin E, 2017, BRACHYTHERAPY, V16, pS56
[35]   True 3D chemical dosimetry (gels, plastics): Development and clinical role [J].
Schreiner, L. J. .
8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
[36]   On the quality assurance and verification of modern radiation therapy treatment [J].
Schreiner, L. John .
JOURNAL OF MEDICAL PHYSICS, 2011, 36 (04) :189-191
[37]  
Schroeder W., 2006, VISUALIZATION TOOLKI, V4th
[38]  
Sharp G., 2010, P 16 INT C US COMP R
[39]   A fast algorithm for gamma evaluation in 3D [J].
Wendling, Markus ;
Zijp, Lambert J. ;
McDermott, Leah N. ;
Smit, Ewoud J. ;
Sonke, Jan-Jakob ;
Mijnheer, Ben J. ;
van Herk, Marcel .
MEDICAL PHYSICS, 2007, 34 (05) :1647-1654
[40]   Sensitivity calibration procedures in optical-CT scanning of BANG®3 polymer gel dosimeters [J].
Xu, Y. ;
Wuu, Cheng-Shie ;
Maryanski, Marek J. .
MEDICAL PHYSICS, 2010, 37 (02) :861-868