摘要
Purpose - This paper aims to show that by using air source heat pump (ASHP) water heater in the residential sector, the energy consumption from sanitary hot water production can be reduced by more than 50 per cent. Hence, this study quantitatively and qualitatively confirms that domestic ASHP water heater is a renewable and energy efficient device for sanitary hot water production. Design/methodology/approach - Design and building of a data acquisition system comprises a data logger, power meters, flow meters, temperature sensors, ambient and relative humidity sensor and an electronic input pulse adapter to monitor the ASHP water heater performance. All the sensors are accommodated by the U30-NRC data logger. The temperature sensors are installed on the inlet pipe containing a flow meter and the outlet pipe of the ASHP unit, the vicinity of both evaporator and expel cold air. An additional temperature sensor and a flow meter that cater for hot water drawn off measurements are incorporated into the data acquisition system (DAS). Findings - The result from a specific monitoring split type ASHP water heater gives an average daily coefficient of performance (COP) of 2.36 and the total electrical energy of 4.15 kWh, and volume of hot water drawn off was 273 L. These results were influenced by ambient temperature and relative humidity. Research limitations/implications - The cost involved in purchasing the entire sensors and data logger limits the number and categories of ASHP water heaters whose performance were going to be monitored. Pressure sensors were excluded in the data acquisition system. Practical implications - The data acquisition system can easily be designed and the logger can also be easily programed. Hence, no high technical or computer skills are needed to install the DAS and to be able to read out the results. Social implications - Hence, the data acquisition system can be installed on the entire domestic Eskom roll out air source heat pump water heaters to effectively determine the coefficient of performance and demand reductions. Originality/value - This DAS is the first of its kind to be built in South Africa to be used to determine the performance of an ASHP water heater with high accuracy and precision. DAS is also robust.
引用
收藏
页码:739 / 751
页数:13
相关论文
共 50 条
  • [1] Performance research on the system of heat pump water heater with energy storage
    Li, Jianxin
    Wang, Yongchuan
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2008, 29 (10): : 1230 - 1234
  • [2] Computational Design of an Optimized Control System for a Split-type Air Source Heat Pump Water Heater
    Yongoua, J.
    Tangwe, S.
    Simon, M.
    PROCEEDINGS OF THE 2017 TWENTY FIFTH INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2017, : 248 - 255
  • [3] Performance and empirical models of a heat pump water heater system with heat recovery of waste water
    Wang, H., 1600, Journal of Chemical and Pharmaceutical Research, 3/668 Malviya Nagar, Jaipur, Rajasthan, India (05):
  • [4] Performance simulation of multiple heat source solar heat pump water heater system
    Yang, Lei
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2009, 60 (09): : 2292 - 2298
  • [5] Performance study on heat pump sub-system in parallel of solar assisted heat pump water heater
    Feng, Shiyu
    Gao, Xiufeng
    Hu, Wei
    Li, Yun
    Gu, Zhaolin
    Wang, Huiyu
    Luo, Cong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (02): : 125 - 129
  • [6] Experimental investigation on system performance of an instant heat pump water heater with combined condenser
    Ju, Fujun
    Mu, Zhenzhen
    Liu, Hongtao
    Fan, Xiaowei
    Hou, Qianlei
    Hou, Lihao
    Liu, Qinglei
    Liu, Wenbo
    Zheng, Huifan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
  • [7] Performance evaluation of a plate type condenser for heat pump water heater
    Asano, Hitoshi
    Honda, Kazuya
    Takeda, Nobuhiro
    Kondo, Masaki
    Nishimura, Kazuhiro
    MECHANICAL ENGINEERING JOURNAL, 2015, 2 (01):
  • [8] Transient behavior and dynamic performance of cascade heat pump water heater with thermal storage system
    Wu, Jianghong
    Yang, Zhaoguang
    Wu, Qinghao
    Zhu, Yujuan
    APPLIED ENERGY, 2012, 91 (01) : 187 - 196
  • [9] Performance analysis on parallel condensing air-source heat pump water heater system
    Wang, Shouchuan
    Wang, Qianxu
    Zhang, Huan
    Wang, Yuxuan
    Zhou, Junhai
    Zhao, Panpan
    Liu, Jiabao
    ENERGY REPORTS, 2022, 8 : 398 - 414
  • [10] Comparison of the operation performance of split and integrated type air source heat pump water heater via modelling and simulation
    Tangwe, Stephen Loh
    Simon, Michael
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 355 - 369