Development of water heater using tubular flame - Heat transfer characteristics on the coiled tube and the inserted tube heat exchangers

被引:2
作者
Matsumoto, Ryosuke [1 ]
Tanikawa, Tatsuro [1 ]
Sugimoto, Tatsuya [1 ]
Ozawa, Mamoru [1 ]
Hisazumi, Yoshinori [2 ]
Hori, Tsukasa [2 ]
Kawai, Noriko [2 ]
Kegasa, Akeshi [2 ]
Shiraga, Yosuke [3 ]
Takemori, Toshikazu [3 ]
Katsuki, Masashi [4 ]
机构
[1] Kansai Univ, Dept Mech Engn, 3-3-35 Yamate Cho, Suita, Osaka 5648680, Japan
[2] Osaka Univ, Dept Mech Engn, Suita, Osaka 5650871, Japan
[3] Osaka Gas Co Ltd, Konohana Ku, Osaka 5540051, Japan
[4] Osaka Univ, Suita, Osaka, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2014年 / 1卷 / 05期
关键词
Tubular flame; Heat transfer coefficient; Swirling flow; Combustion gas; Water heater; Home CHP;
D O I
10.1299/mej.2014tep0047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The purpose of this study is to develop the compact auxiliary water heater using tubular flame for home CHP (combined heat and power). The tubular-flame water-heater consists of the tubular flame burner, the coiled tube heat exchanger and the inserted tube installed at the center of the coiled tube as an additional heat exchanger. The tubular flame is formed in a rotating flow field by injecting the air-fuel mixture tangentially into the cylindrical chamber. The swirling flow of the combustion gas flows through the gap between the coiled tube and inserted tube. The high heat transfer performance can be achieved on these heat exchangers without the expanded heat transfer surface due to the swirling flow. Thus, the compact water heater can be constructed by using the tubular flame burner. At the first stage of the development, the maximum thermal efficiency achieves 81 % at the combustion rate of 15 kW. The heat transfer characteristics on the coiled tube and the inserted tube is investigated under the combustion and non-combustion conditions. Heat transfer coefficient on the coiled tube has about 5.6 times higher than that under the no-swirling flow condition at the same flow rate. Nusselt number on the coiled tube heat exchanger and the inserted tube can be estimated by Dhir's correlation equation for the swirling flow, which was provided as a function of the ratio between tangential momentum and axial momentum. The heat transfer characteristics on not only the coiled tube but the inserted tube was dominated by the swirling convection flow.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Fluid-to-particle heat transfer coefficients for continuous flow of suspensions in coiled tube and straight tube with bends
    Chakrabandhu, K
    Singh, RK
    LEBENSMITTEL-WISSENSCHAFT UND-TECHNOLOGIE-FOOD SCIENCE AND TECHNOLOGY, 2002, 35 (05): : 420 - 435
  • [32] Application of ZnO/TiO2 Nanocomposite for the Improvement of Heat Transfer Coefficient in Tube Heat Exchangers
    Yousefifar, Marzieh
    Zerafat, Mohammad Mahdi
    Sabbaghi, Samad
    JOURNAL OF NANOANALYSIS, 2019, 6 (01): : 33 - 40
  • [33] Experimental Investigation of the Heat Transfer Characteristics of Plate Heat Exchangers Using LiBr/Water as Working Fluid
    Yong, Junhyeok
    Ham, Junggyun
    Kwon, Ohkyung
    Cho, Honghyun
    ENERGIES, 2021, 14 (20)
  • [34] Hydrodynamic and heat transfer characteristics of glass bead-water flow in a vertical tube
    Kim, NH
    Lee, YP
    DESALINATION, 2001, 133 (03) : 233 - 243
  • [35] Experimental and numerical study on the heat transfer characteristic of supercritical water with high mass velocity in a helically coiled tube
    Chang, Fucheng
    Hu, He
    Shang, Yuhao
    Hu, Yongpeng
    Li, Xi
    Lei, Hailin
    Li, Huixiong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 197
  • [36] Flow Boiling Heat Transfer Characteristics of Methane in a Horizontal Tube
    Wang, S.
    Gong, M. Q.
    Chen, G. F.
    Sun, Z. H.
    Wu, J. F.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1512 - 1518
  • [37] Numerical and Experimental Study of Finned Tube Heat Transfer Characteristics
    Petrik, Mate
    Szepesi, Gabor L.
    Varga, Tibor
    VEHICLE AND AUTOMOTIVE ENGINEERING 2, VAE2018, 2018, : 563 - 570
  • [38] FLOW BOILING HEAT TRANSFER CHARACTERISTICS OF HEXAFLUOROETHANE IN A HORIZONTAL TUBE
    Wang, S.
    Gong, M. Q.
    Chen, G. F.
    Wu, J. F.
    Sun, Z. H.
    Zou, X.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 740 - 746
  • [39] Experimental determination of the heat transfer coefficients of shell-and-tube heat exchangers with different hollow fiber arrangements
    Strunga, Alan
    Kroulikova, Tereza
    Bartuli, Erik
    Raudensky, Miroslav
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (24) : 14787 - 14796
  • [40] The effect of flexible tube vibration on pressure drop and heat transfer in heat exchangers considering viscous dissipation effects
    H. Shokouhmand
    F. Sangtarash
    Heat and Mass Transfer, 2008, 44 : 1435 - 1445