Development of water heater using tubular flame - Heat transfer characteristics on the coiled tube and the inserted tube heat exchangers

被引:2
作者
Matsumoto, Ryosuke [1 ]
Tanikawa, Tatsuro [1 ]
Sugimoto, Tatsuya [1 ]
Ozawa, Mamoru [1 ]
Hisazumi, Yoshinori [2 ]
Hori, Tsukasa [2 ]
Kawai, Noriko [2 ]
Kegasa, Akeshi [2 ]
Shiraga, Yosuke [3 ]
Takemori, Toshikazu [3 ]
Katsuki, Masashi [4 ]
机构
[1] Kansai Univ, Dept Mech Engn, 3-3-35 Yamate Cho, Suita, Osaka 5648680, Japan
[2] Osaka Univ, Dept Mech Engn, Suita, Osaka 5650871, Japan
[3] Osaka Gas Co Ltd, Konohana Ku, Osaka 5540051, Japan
[4] Osaka Univ, Suita, Osaka, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2014年 / 1卷 / 05期
关键词
Tubular flame; Heat transfer coefficient; Swirling flow; Combustion gas; Water heater; Home CHP;
D O I
10.1299/mej.2014tep0047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The purpose of this study is to develop the compact auxiliary water heater using tubular flame for home CHP (combined heat and power). The tubular-flame water-heater consists of the tubular flame burner, the coiled tube heat exchanger and the inserted tube installed at the center of the coiled tube as an additional heat exchanger. The tubular flame is formed in a rotating flow field by injecting the air-fuel mixture tangentially into the cylindrical chamber. The swirling flow of the combustion gas flows through the gap between the coiled tube and inserted tube. The high heat transfer performance can be achieved on these heat exchangers without the expanded heat transfer surface due to the swirling flow. Thus, the compact water heater can be constructed by using the tubular flame burner. At the first stage of the development, the maximum thermal efficiency achieves 81 % at the combustion rate of 15 kW. The heat transfer characteristics on the coiled tube and the inserted tube is investigated under the combustion and non-combustion conditions. Heat transfer coefficient on the coiled tube has about 5.6 times higher than that under the no-swirling flow condition at the same flow rate. Nusselt number on the coiled tube heat exchanger and the inserted tube can be estimated by Dhir's correlation equation for the swirling flow, which was provided as a function of the ratio between tangential momentum and axial momentum. The heat transfer characteristics on not only the coiled tube but the inserted tube was dominated by the swirling convection flow.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Visualization and determination of local heat transfer coefficients in shell-and-tube heat exchangers for in-line tube arrangement by mass transfer measurements
    H. D. Li
    V. Kottke
    Heat and Mass Transfer, 1998, 33 : 371 - 376
  • [22] Comparative analysis of heat transfer and pressure drop in helically segmented finned tube heat exchangers
    Martinez, E.
    Vicente, W.
    Soto, G.
    Salinas, M.
    APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) : 1470 - 1476
  • [23] ESTIMATION OF THE CONDENSATION HEAT TRANSFER COEFFICIENT FOR STEAM WATER AT LOW PRESSURE IN A COILED DOUBLE TUBE CONDENSER INTEGRATED TO A HEAT TRANSFORMER
    Flores, O.
    Velazquez, V.
    Meza, M.
    Horacio, H.
    Juarez, D.
    Hernandez, J. A.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2013, 12 (02): : 303 - 313
  • [24] Enhanced heat transfer characteristics of the mini hexagonal tube heat sink using hybrid nanofluids
    Sriharan, G.
    Harikrishnan, S.
    Ali, Hafiz Muhammad
    NANOTECHNOLOGY, 2022, 33 (47)
  • [25] Heat transfer characteristics of high temperature and pressure water in vertical downward tube
    Shen, Zhi
    Yang, Dong
    Chen, Gongming
    Xiao, Feng
    Huagong Xuebao/CIESC Journal, 2013, 64 (07): : 2386 - 2393
  • [26] Condensing heat transfer characteristics of aluminum flat tube
    Chang, YP
    Tsai, R
    Hwang, JW
    APPLIED THERMAL ENGINEERING, 1997, 17 (11) : 1055 - 1065
  • [27] HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SPIRAL FINS UNDER WET CONDITIONS
    Jin-Wook, Lee
    Nae-Hyun, Kim
    Hyun-Min, Sim
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (03) : 185 - 193
  • [28] Numerical estimation of heat transfer characteristics for two-row plate-finned tube heat exchangers with experimental data
    Han-Taw Chen
    Chih-Han Lu
    Yao-Sheng Huang
    Kuo-Chi Liu
    Heat and Mass Transfer, 2016, 52 : 969 - 979
  • [29] Investigation of Effects of Heater Tube Angle on the Pool Boiling Heat Transfer Coefficient
    Khooshehchin, Mohsen
    Fathi, Sohrab
    Salimi, Farhad
    Ovaysi, Saeed
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2022, 41 (03): : 957 - 970
  • [30] Heat transfer enhancement of shell-and-coiled tube heat exchanger utilizing helical wire turbulator
    Panahi, Davood
    Zamzamian, Kamiar
    APPLIED THERMAL ENGINEERING, 2017, 115 : 607 - 615