Development of water heater using tubular flame - Heat transfer characteristics on the coiled tube and the inserted tube heat exchangers

被引:2
作者
Matsumoto, Ryosuke [1 ]
Tanikawa, Tatsuro [1 ]
Sugimoto, Tatsuya [1 ]
Ozawa, Mamoru [1 ]
Hisazumi, Yoshinori [2 ]
Hori, Tsukasa [2 ]
Kawai, Noriko [2 ]
Kegasa, Akeshi [2 ]
Shiraga, Yosuke [3 ]
Takemori, Toshikazu [3 ]
Katsuki, Masashi [4 ]
机构
[1] Kansai Univ, Dept Mech Engn, 3-3-35 Yamate Cho, Suita, Osaka 5648680, Japan
[2] Osaka Univ, Dept Mech Engn, Suita, Osaka 5650871, Japan
[3] Osaka Gas Co Ltd, Konohana Ku, Osaka 5540051, Japan
[4] Osaka Univ, Suita, Osaka, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2014年 / 1卷 / 05期
关键词
Tubular flame; Heat transfer coefficient; Swirling flow; Combustion gas; Water heater; Home CHP;
D O I
10.1299/mej.2014tep0047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The purpose of this study is to develop the compact auxiliary water heater using tubular flame for home CHP (combined heat and power). The tubular-flame water-heater consists of the tubular flame burner, the coiled tube heat exchanger and the inserted tube installed at the center of the coiled tube as an additional heat exchanger. The tubular flame is formed in a rotating flow field by injecting the air-fuel mixture tangentially into the cylindrical chamber. The swirling flow of the combustion gas flows through the gap between the coiled tube and inserted tube. The high heat transfer performance can be achieved on these heat exchangers without the expanded heat transfer surface due to the swirling flow. Thus, the compact water heater can be constructed by using the tubular flame burner. At the first stage of the development, the maximum thermal efficiency achieves 81 % at the combustion rate of 15 kW. The heat transfer characteristics on the coiled tube and the inserted tube is investigated under the combustion and non-combustion conditions. Heat transfer coefficient on the coiled tube has about 5.6 times higher than that under the no-swirling flow condition at the same flow rate. Nusselt number on the coiled tube heat exchanger and the inserted tube can be estimated by Dhir's correlation equation for the swirling flow, which was provided as a function of the ratio between tangential momentum and axial momentum. The heat transfer characteristics on not only the coiled tube but the inserted tube was dominated by the swirling convection flow.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Numerical Studies on Thermal and Hydrodynamic Characteristics of LNG in Helically Coiled Tube-in-Tube Heat Exchangers
    Yan, Fayi
    Pei, Xuejian
    Lu, He
    Zong, Shuzhen
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 (01): : 287 - 304
  • [2] Experimental and numerical study on unsteady natural convection heat transfer in helically coiled tube heat exchangers
    E. Neshat
    S. Hossainpour
    F. Bahiraee
    Heat and Mass Transfer, 2014, 50 : 877 - 885
  • [3] Experimental and numerical study on unsteady natural convection heat transfer in helically coiled tube heat exchangers
    Neshat, E.
    Hossainpour, S.
    Bahiraee, F.
    HEAT AND MASS TRANSFER, 2014, 50 (06) : 877 - 885
  • [4] Heat transfer characteristics of a new helically coiled crimped spiral finned tube heat exchanger
    Kwanchanok Srisawad
    Somchai Wongwises
    Heat and Mass Transfer, 2009, 45 : 381 - 391
  • [5] Effect of tube pitch on heat transfer in shell-and-tube heat exchangers—new simulation software
    A. Karno
    S. Ajib
    Heat and Mass Transfer, 2006, 42 : 263 - 270
  • [6] Heat transfer characteristics of flat plate finned-tube heat exchangers with large fin pitch
    Kim, Y
    Kim, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 851 - 858
  • [7] Experimental research on heat transfer coefficients for cryogenic cross-counter-flow coiled finned-tube heat exchangers
    Gupta, Prabhat Kumar
    Kush, P. K.
    Tiwari, Ashesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 960 - 972
  • [8] Studying the Thermal and Hydraulic Characteristics of a Shell-and-Tube Water Heater Equipped with Dimpled Heat-Transfer Tubes to Enhance Heat Transfer
    B. F. Balunov
    M. A. Gotovskii
    V. A. Permyakov
    K. V. Permyakov
    A. A. Shcheglov
    V. A. Il’in
    E. N. Saikova
    V. V. Sal’nikov
    Thermal Engineering, 2008, 55 (1) : 67 - 71
  • [9] Determination of heat transfer correlations for plate-fin-and-tube heat exchangers
    Dawid Taler
    Heat and Mass Transfer, 2004, 40 : 809 - 822
  • [10] Heat transfer simulation in a helically coiled tube steam generator
    Bazargan Hassanzadeh
    Ali Keshavarz
    Masood Ebrahimi
    Heat and Mass Transfer, 2014, 50 : 13 - 21