Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children

被引:1
作者
Rafael Parra-Bravo, Jose [1 ]
Apolonio-Martinez, Adriana [2 ]
de Jesus Estrada-Loza, Maria [1 ]
Gracia Beirana-Palencia, Luisa [1 ]
Ivan Ramirez-Portillo, Cesar [1 ]
机构
[1] Inst Mexicano Seguro Social, Hosp Pediat Ctr Med Nacl Siglo 21, Serv Cardiol & Hemodinamia, Mexico City, DF, Mexico
[2] Inst Mexicano Seguro Social, Hosp Pediat Ctr Medico Nacl Siglo 21, Serv Pediat, Mexico City, DF, Mexico
来源
ARCHIVOS DE CARDIOLOGIA DE MEXICO | 2015年 / 85卷 / 03期
关键词
Patent ductus arteriosus; Percutaneous closure; Amplatzer Duct Occluder; Lung perfusion scan; Mexico;
D O I
10.1016/j.acmx.2014.12.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Methods: Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion < 40% was considered abnormal. Results: The device implantation was successful in all patients. Average perfusion of left lung was 44.7 +/- 4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. Conclusion: The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. (C) 2014 Instituto Nacional de Cardiologia Ignacio Chavez. Published by Masson Doyma Mexico S.A. All rights reserved.
引用
收藏
页码:188 / 194
页数:7
相关论文
共 27 条
  • [1] The efficacy and safety of the Amplatzer ductal occluder in young children and infants
    Al-Ata, J
    Arfi, AM
    Hussain, A
    Kouatli, AA
    Jalal, MO
    [J]. CARDIOLOGY IN THE YOUNG, 2005, 15 (03) : 279 - 285
  • [2] The Amplatzer duct occluder: Experience in 209 patients
    Bilkis, AA
    Alwi, M
    Hasri, S
    Haifa, AL
    Geetha, K
    Rehman, MA
    Hasanah, I
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 258 - 261
  • [3] Transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder in very young symptomatic children
    Butera, G
    De Rosa, G
    Chessa, M
    Piazza, L
    Delogu, A
    Frigiola, A
    Carminati, M
    [J]. HEART, 2004, 90 (12) : 1467 - 1470
  • [4] Cervantes-Salazar J, 2013, REV INVEST CLIN, V65, P476
  • [5] Long-term Follow-up Results of Lung Perfusion Studies after Transcatheter Closure of Patent Ductus Arteriosus
    Demir, Fadli
    Celebi, Ahmet
    Saritas, Turkay
    Erdem, Abdullah
    Demir, Halil
    Firat, Mehmet Fatih
    Polat, Tugcin Bora
    [J]. CONGENITAL HEART DISEASE, 2013, 8 (02) : 159 - 166
  • [6] Echocardiographic and radionuclide pulmonary blood flow patterns after transcatheter closure of patent ductus arteriosus
    Dessy, H
    Hermus, JPS
    vandenHeuvel, F
    Oei, HY
    Krenning, EP
    Hess, J
    [J]. CIRCULATION, 1996, 94 (02) : 126 - 129
  • [7] Effect of multiple coil closure of patent ductus arteriosus on blood flow to the left lung as determined by lung perfusion scans
    Evangelista, JK
    Hijazi, ZM
    Geggel, RL
    Oates, E
    Fulton, DR
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (02) : 242 - 244
  • [8] Faella HJ, 2000, CATHETER CARDIO INTE, V51, P50, DOI 10.1002/1522-726X(200009)51:1<50::AID-CCD11>3.0.CO
  • [9] 2-6
  • [10] Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder
    Fischer, G
    Stieh, J
    Uebing, A
    Grabitz, R
    Kramer, HH
    [J]. HEART, 2001, 86 (04) : 444 - 447