PHYSIOLOGICAL ASSESSMENT OF AUGMENTED VASCULARITY INDUCED BY VEGF IN ISCHEMIC RABBIT HINDLIMB

被引:146
作者
BAUTERS, C
ASAHARA, T
ZHENG, LP
TAKESHITA, S
BUNTING, S
FERRARA, N
SYMES, JF
ISNER, JM
机构
[1] TUFTS UNIV, SCH MED,ST ELIZABETHS MED CTR,DEPT MED,DIV CARDIOL, BOSTON, MA 02135 USA
[2] TUFTS UNIV, SCH MED,ST ELIZABETHS MED CTR,DEPT SURG, DIV CARDIOVASC, BOSTON, MA 02135 USA
[3] TUFTS UNIV, SCH MED, ST ELIZABETHS MED CTR, DEPT BIOMED RES, BOSTON, MA 02135 USA
[4] GENENTECH INC, DEPT CARDIOVASC RES, San Francisco, CA 94080 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1994年 / 267卷 / 04期
关键词
DOPPLER; COLLATERAL VESSELS; BLOOD FLOW;
D O I
10.1152/ajpheart.1994.267.4.H1263
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed to assess the physiological consequences of augmented vascularity induced by administration of vascular endothelial growth factor (VEGF), an endothelial cell-specific mitogen, in a rabbit model of hindlimb ischemia. Ten days after excision of the common and superficial femoral arteries from one hindlimb of 24 New Zealand White rabbits, VEGF (n = 15) or saline (control; n = 9) was selectively injected into the ipsilateral internal iliac artery. Limb perfusion was evaluated immediately pre-VEGF (baseline) and again at days 10 and 30. A Doppler guide wire was advanced to the internal iliac artery to record flow velocity at rest and at maximum flow velocity provoked by intra-arterial injection of papaverine. At baseline and at day 10, no differences in flow parameters were observed between the control and the VEGF-treated animals. By day 30, however, flow at rest (P < 0.05), maximum flow velocity (P < 0.001), and maximum blood flow (P < 0.001) were all significantly higher in the VEGF-treated group. These physiological findings complement previous anatomic studies by providing evidence that a single intra-arterial bolus of VEGF augments flow, particularly maximum flow, in the rabbit ischemic hindlimb. These data thus support the notion that VEGF administration represents a potential treatment strategy for certain patients with lower extremity ischemia.
引用
收藏
页码:H1263 / H1271
页数:9
相关论文
共 25 条
[1]   ENHANCED ANGIOGENESIS AND GROWTH OF COLLATERALS BY INVIVO ADMINISTRATION OF RECOMBINANT BASIC FIBROBLAST GROWTH-FACTOR IN A RABBIT MODEL OF ACUTE LOWER-LIMB ISCHEMIA - DOSE-RESPONSE EFFECT OF BASIC FIBROBLAST GROWTH-FACTOR [J].
BAFFOUR, R ;
BERMAN, J ;
GARB, JL ;
RHEE, SW ;
KAUFMAN, J ;
FRIEDMANN, P .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (02) :181-191
[2]   HEPARIN ACCELERATES CORONARY COLLATERAL DEVELOPMENT IN A PORCINE MODEL OF CORONARY-ARTERY OCCLUSION [J].
CARROLL, SM ;
WHITE, FC ;
ROTH, DM ;
BLOOR, CM .
CIRCULATION, 1993, 88 (01) :198-207
[3]   AN INVESTIGATION OF ARTERIAL INSUFFICIENCY IN RAT HINDLIMB - A COMBINED P-31-NMR AND BLOODFLOW STUDY [J].
CHALLISS, RAJ ;
HAYES, DJ ;
PETTY, RFH ;
RADDA, GK .
BIOCHEMICAL JOURNAL, 1986, 236 (02) :461-467
[4]   PHASIC CORONARY BLOOD-FLOW VELOCITY IN INTRAMURAL AND EPICARDIAL CORONARY-ARTERIES [J].
CHILIAN, WM ;
MARCUS, ML .
CIRCULATION RESEARCH, 1982, 50 (06) :775-781
[5]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[6]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[7]  
FERRARA N, 1991, METHOD ENZYMOL, V198, P391
[8]   THE VASCULAR ENDOTHELIAL GROWTH-FACTOR FAMILY OF POLYPEPTIDES [J].
FERRARA, N ;
HOUCK, KA ;
JAKEMAN, LB ;
WINER, J ;
LEUNG, DW .
JOURNAL OF CELLULAR BIOCHEMISTRY, 1991, 47 (03) :211-218
[9]  
GITAYGOREN H, 1992, J BIOL CHEM, V267, P6093
[10]  
HOUCK KA, 1992, J BIOL CHEM, V267, P26031