A MEASUREMENT OF PULMONARY BLOOD-VOLUME INCREASE DURING SYSTOLE IN HUMANS

被引:5
|
作者
NITZAN, M
MAHLER, Y
SCHECHTER, D
YAFFE, S
BOCHER, M
CHISIN, R
机构
[1] HADASSAH UNIV HOSP,DEPT BIOMED ENGN,IL-91120 JERUSALEM,ISRAEL
[2] HADASSAH UNIV HOSP,DEPT NUCL MED & BIOPHYS,IL-91120 JERUSALEM,ISRAEL
关键词
Radioisotopes;
D O I
10.1088/0967-3334/15/4/010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measured and the relative pulmonary systolic blood volume increase (SBVI)-the ratio between the pulmonary SBVI and the cardiac stroke volume-was calculated. The relative pulmonary SBVI, which is a measure for the compliance of the pulmonary blood vessels, was found to be 0.26-0.85, and the average Value was 0.57 +/- 0.15. The relative pulmonary SBVI was inversely correlated with the patient age (r = 0.27, p < 0.05) and with the left ventricular ejection fraction and stroke volume (r = 0.36, p < 0.01) due to decreased arterial compliance for older patients and for increased pulmonary blood volume respectively. The correlation coefficients were not high, indicating that the compliance of the patients is determined mainly by other individual factors. Radionuclide plethysmography enables qualitative assessment of pulmonary arterial compliance.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 50 条
  • [31] EFFECTS OF LIQUID OVERLOAD ON TOTAL BLOOD-VOLUME, PULMONARY BLOOD-VOLUME AND EXTRAVASCULAR PULMONARY WATER IN NORMAL HUMAN BEING
    EVEN, P
    DUROUX, P
    RUFF, F
    CAUBARRE.I
    PARROT, JL
    JOURNAL DE PHYSIOLOGIE, 1972, 65 (03): : A403 - A404
  • [32] ECG GATED RADIONUCLIDE PLETHYSMOGRAPHY - A METHOD FOR THE ASSESSMENT OF PULMONARY SYSTOLIC BLOOD-VOLUME INCREASE
    NITZAN, M
    MAHLER, Y
    YAFFE, S
    MARZIANO, R
    BOCHER, M
    CHISIN, R
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01): : 21 - 28
  • [33] A NEW METHOD OF CONTINUOUS HEMOGLOBINOMETRIC MEASUREMENT OF BLOOD-VOLUME DURING HEMODIALYSIS
    SCHALLENBERG, U
    STILLER, S
    MANN, H
    LIFE SUPPORT SYSTEMS, 1987, 5 (04): : 293 - 305
  • [34] CONTINUOUS REGISTRATION OF BLOOD-VOLUME CHANGES DURING HEMODIALYSIS BY ULTRASONIC MEASUREMENT
    ROOB, JM
    SCHNEDITZ, D
    HAAS, GM
    HORINA, JH
    POGGLITSCH, H
    WIENER KLINISCHE WOCHENSCHRIFT, 1990, 102 (05) : 131 - 136
  • [35] THE EFFECT OF VENTILATION ON PULMONARY CAPILLARY BLOOD-VOLUME (VC) AS ASSESSED BY THE MEASUREMENT OF ARTERIAL BLOOD DENSITY
    LEE, JS
    LEE, LP
    FEDERATION PROCEEDINGS, 1986, 45 (04) : 1128 - 1128
  • [36] RESPIRATORY EFFECT ON THE BLOOD-VOLUME OF PULMONARY CAPILLARIES
    LEE, JS
    FALLON, T
    HUNTER, M
    YE, Q
    LEE, LP
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (02): : 150 - 154
  • [37] BAROREFLEX RESPONSES TO ACUTE CHANGES IN BLOOD-VOLUME IN HUMANS
    THOMPSON, CA
    TATRO, DL
    LUDWIG, DA
    CONVERTINO, VA
    AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (04): : R792 - R798
  • [38] PULMONARY BLOOD-VOLUME IN CHRONIC-BRONCHITIS
    VALETTE, H
    DUHAZE, P
    HEBERT, JL
    LOCKHART, A
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1976, 6 (04) : 324 - 324
  • [39] EFFECTS OF RADIATION ON SKIN BLOOD-VOLUME PULSE IN HUMANS
    ZANELLI, GD
    BRITISH JOURNAL OF RADIOLOGY, 1977, 50 (589): : 68 - 70
  • [40] EFFECT OF VASOCONSTRICTORS ON THE BLOOD-VOLUME OF PULMONARY CAPILLARIES
    LEE, JS
    LEE, LP
    EVANS, MV
    FEDERATION PROCEEDINGS, 1985, 44 (03) : 625 - 625