Electrical impedance tomography in the clinical assessment of lung volumes following recruitment manoeuvres

被引:8
作者
Caruana, Lawrence [1 ,2 ]
Paratz, Jennifer [1 ,3 ]
Chang, Angela [4 ]
Fraser, John [1 ,2 ]
机构
[1] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[2] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld, Australia
[3] Univ Queensland, Burns Trauma & Crit Care Res Ctr, Brisbane, Qld, Australia
[4] Univ Queensland, Sch Hlth & Rehabil Sci, Brisbane, Qld, Australia
关键词
Electrical impedance tomography; End expiratory lung volumes; Functional residual capacity; Lung volumes; Recruitment;
D O I
10.1179/1743288X10Y.0000000021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Mechanical ventilation has dramatically improved outcomes in critically ill patients with respiratory failure. Minimizing volumes and higher positive end-expiratory pressures can further improve patient outcomes. Recruitment manoeuvres which can be used to individualize positive end-expiratory pressure may not improve outcome unless recruitable tissue is present. Existing methods of assessing if lung tissue is recruitable have a variety of limitations. Electrical impedance tomography (EIT) is a new technology that may be able to assess whether or not lung tissue is recruitable at the bedside. Objectives: This review will assess the growing body of evidence that EIT is a promising technique which may help the clinician to optimize ventilation, while minimizing injury. We will review how the device works, the data supporting its use, and potential uses for the physical therapist in the critical care environment. Major findings: EIT is a technique of injecting current through tissue, and measuring the difference between an array of electrodes. The difference relates to the changes of volume within the chest cavity-either blood or gas. It is reproducible, non-radiative, and real-time-allowing immediate and repeated imaging in the sickest of patients, who may require high levels of peep and recruitment manoeuvres. Conclusions: This paper has demonstrated that with an understanding of the strengths and limitations of the device, EIT can be used successfully at the bedside by clinicians to guide recruitment and other clinical techniques.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 75 条
  • [1] Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    Adler, A
    Amyot, R
    Guardo, R
    Bates, JHT
    Berthiaume, Y
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) : 1762 - 1767
  • [2] Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients
    Bikker, Ido G.
    Leonhardt, Steffen
    Miranda, Dinis Reis
    Bakker, Jan
    Gommers, Diederik
    [J]. CRITICAL CARE, 2010, 14 (03):
  • [3] Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels
    Bikker, Ido G.
    Leonhardt, Steffen
    Bakker, Jan
    Gommers, Diederik
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (08) : 1362 - 1367
  • [4] End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions
    Bikker, Ido G.
    van Bommel, Jasper
    Miranda, Dinis Reis
    Bakker, Jan
    Gommers, Diederik
    [J]. CRITICAL CARE, 2008, 12 (06):
  • [5] Principles of electrical impedance tomography and its clinical application
    Bodenstein, Marc
    David, Matthias
    Markstaller, Klaus
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (02) : 713 - 724
  • [6] Brower RG, 2004, NEW ENGL J MED, V351, P327
  • [7] Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.
    Brower, RG
    Matthay, MA
    Morris, A
    Schoenfeld, D
    Thompson, BT
    Wheeler, A
    Wiedemann, HP
    Arroliga, AC
    Fisher, CJ
    Komara, JJ
    Perez-Trepichio, P
    Parsons, PE
    Wolkin, R
    Welsh, C
    Fulkerson, WJ
    MacIntyre, N
    Mallatratt, L
    Sebastian, M
    McConnell, R
    Wilcox, C
    Govert, J
    Thompson, D
    Clemmer, T
    Davis, R
    Orme, J
    Weaver, L
    Grissom, C
    Eskelson, M
    Young, M
    Gooder, V
    McBride, K
    Lawton, C
    d'Hulst, J
    Peerless, JR
    Smith, C
    Brownlee, J
    Pluss, W
    Kallet, R
    Luce, JM
    Gottlieb, J
    Elmer, M
    Girod, A
    Park, P
    Daniel, B
    Gropper, M
    Abraham, E
    Piedalue, F
    Glodowski, J
    Lockrem, J
    McIntyre, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) : 1301 - 1308
  • [8] APPLIED POTENTIAL TOMOGRAPHY - POSSIBLE CLINICAL-APPLICATIONS
    BROWN, BH
    BARBER, DC
    SEAGAR, AD
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1985, 6 (02): : 109 - 121
  • [9] BRYAN AC, 1974, AM REV RESPIR DIS, V110, P143
  • [10] How to monitor lung recruitment in patients with acute lung injury
    Caironi, Pietro
    Gattinoni, Luciano
    [J]. CURRENT OPINION IN CRITICAL CARE, 2007, 13 (03) : 338 - 343