DETERMINATION OF TRACE NON RARE-EARTH ELEMENTS IN HIGH-PURITY RARE-EARTH-OXIDES BY ICP-AES WITH MICROCOLUMN PRECONCENTRATION IN A FLOW-INJECTION SYSTEM

被引:0
|
作者
JI, HN [1 ]
LIAO, ZH [1 ]
JIANG, ZC [1 ]
XIE, J [1 ]
机构
[1] WUHAN UNIV,DEPT CHEM,WUHAN 430072,PEOPLES R CHINA
关键词
FLOW INJECTION; ICP-AES; ACTIVE CARBON SILICA GEL; SODIUM DIETHYLDITHIOCARBAMATE; STOP-FLOW TECHNIQUE; MICROCOLUMN PRECONCENTRATION; HIGH PURITY EU2O3;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new-method for the determination of trace non-rare earth elements in high purity rare earth oxides by ICP-AES with preconcentration on an active carbon-silica gel microcolumn in a flow injection system is described in this paper. Experimental parameters such as pH, flow rate, reagent concentration, length of reaction coil, eluent acidity, etc. were optimized. In the buffer solution of NH3 . H2O/NH4Cl at pH 4.6, Al, Cr, Cu, Fe, Pb, V and Zn can be preconcentrated and then eluted with 4.5 mol/L nitric acid utilizing stop-flow technique. The enrichment factors were in range of 8.1 similar to 12.6 With detection limits of mu g/mL level, and the RSD with metals at mu g/g level were 2.3 similar to 5.0% (n = 7). The method proposed can reduce the matrix interference effectively, and has been applied to the determination of non-rare earth metals at mu g/g level in high purity Eu2O3 With satisfactory results.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 16 条
  • [1] Determination of Trace Non Rare Earth Elements in High Purity Rare Earth Oxides by ICP-AES with Microcolumn Preconcentration in a Flow Injection System
    吉红念
    廖振环
    江祖成
    谢金娥
    JOURNALOFRAREEARTHS, 1995, (02) : 119 - 124
  • [2] Direct determination of rare earth elements in rare earth chloride and light rare earth oxide by ICP-AES
    Bian, QZ
    Peng, SB
    He, BL
    Zhong, ZG
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (03) : 357 - 360
  • [3] DETERMINATION OF TRACES OF CALCIUM AND MAGNESIUM IN RARE-EARTH-OXIDES BY FLOW-INJECTION ANALYSIS
    THUY, DT
    DECNOPWEEVER, D
    KOK, WT
    LUAN, P
    NGHI, TV
    ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) : 151 - 157
  • [4] Determination of major and rare earth elements in bastnasite ores by ICP-AES
    Yenisoy-Karakas, S
    Gaga, EO
    Dogangun, A
    Tuncel, SG
    ANALYTICAL LETTERS, 2004, 37 (13) : 2701 - 2709
  • [5] Determination of Rare Earth Elements and Non-Rare Earth Elements in Leaching Solution with Magnesium Salt System of Ion-Adsorption Type Rare Earth Ore by ICP-AES
    Xiao Y.
    Huang L.
    Li M.
    Feng Z.
    Long Z.
    Wang L.
    Xiyou Jinshu/Chinese Journal of Rare Metals, 2017, 41 (04): : 390 - 397
  • [6] Determination of rare earth elements in trialkyl phoshine oxide (TRPO)-kerosene by ICP-AES
    Zhang, L
    Wang, JC
    Xin, RX
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (10) : 1684 - 1687
  • [7] Determination of Trace Rare Earth Elements in Biological Samples by ICP-AES with Tungsten-spiral Electrothermal Vaporization Sampling
    梅二文
    刘慧
    廖振环
    江祖成
    JournalofRareEarths, 1993, (01) : 52 - 57
  • [9] Determination of uranium in natural waters and high-purity aluminum by flow-injection on-line preconcentration and ICP-MS detection
    Seki, T
    Oguma, K
    BUNSEKI KAGAKU, 2004, 53 (04) : 353 - 357
  • [10] Spectral interferences of rare earth elements with a high resolution sequential ICP-AES - IV. Spectral interferences of europium and gadolinium
    Sun, ZH
    Sun, DH
    Gu, S
    Ying, H
    Wang, XR
    Huang, BL
    Li, B
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (01) : 49 - 54