NONINVASIVE MONITORING OF CARDIAC-OUTPUT BY DOPPLER-ECHOCARDIOGRAPHY IN PATIENTS TREATED WITH VOLUME EXPANSION AFTER SUBARACHNOID HEMORRHAGE

被引:14
|
作者
MAYER, SA
SHERMAN, D
FINK, ME
HOMMA, S
SOLOMON, RA
LENNIHAN, L
BECKFORD, A
KLEBANOFF, LM
机构
[1] COLUMBIA PRESBYTERIAN MED CTR,DEPT MED,DIV CARDIOL,NEW YORK,NY 10032
[2] COLUMBIA PRESBYTERIAN MED CTR,DEPT NEUROSURG,NEW YORK,NY 10032
关键词
SUBARACHNOID HEMORRHAGE; CARDIAC OUTPUT; ECHOCARDIOGRAPHY; DOPPLER; PULMONARY ARTERY CATHETER; THERMODILUTION; VASOSPASM; ALBUMIN; MONITORING; PHYSIOLOGICAL; CRITICAL ILLNESS;
D O I
10.1097/00003246-199509000-00005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess the validity and potential clinical utility of cardiac output monitoring using Doppler echocardiography in patients treated with volume expansion after subarachnoid hemorrhage, Design: Observational study of patients in a randomized, clinical trial, Setting: Neurologic intensive care unit, Patients: Simultaneous, blinded measurements of cardiac output by thermodilution and Doppler echocardiography were performed in 48 patients 1 or 2 days after aneurysmal clipping, Follow-up Doppler echocardiography was performed an average of 3.9 days later (range 3 to 6) in 15 patients assigned to normovolemia and 24 patients assigned to hypervolemia, Intervention: Patients received supplemental 5% albumin in order to maintain increased (hypervolemia) or normal (normovolemia) cardiac filling pressures, Measurements and Main Results: The overall degree of correlation between the two measures was moderate (r = .67, r(2) = .45, p < .0001), Bias and precision calculations (-0.75 +/- 1.34 L/min) showed a tendency for Doppler echocardiography to underestimate thermodilution, particularly when cardiac output was very high, Although hypervolemia patients received more 5% albumin than normovolemia patients, mean percent change in Doppler echocardiography cardiac output did not differ between the two groups, Multiple regression analysis showed that the percent change in Doppler echocardiography cardiac output correlated strongly with changes in heart rate (p < .0001), but not with daily net fluid balance or 5% albumin administration, Conclusions: Agreement was poor between Doppler echocardiography and thermodilution measurements of cardiac output, and trends reflected variations in heart rate rather than fluid status, Monitoring of cardiac output by this technique cannot be recommended in patients treated with volume expansion after subarachnoid hemorrhage.
引用
收藏
页码:1470 / 1474
页数:5
相关论文
共 15 条
  • [1] VALIDATION OF CARDIAC-OUTPUT MEASUREMENTS WITH NONINVASIVE DOPPLER-ECHOCARDIOGRAPHY BY THERMODILUTION AND FICK METHODS IN NEWBORN PIGLETS
    WELCH, E
    DUARA, S
    SUGUIHARA, C
    BANDSTRA, E
    BANCALARI, E
    BIOLOGY OF THE NEONATE, 1994, 66 (2-3): : 137 - 145
  • [2] COMPARISON OF METHODS OF CARDIAC-OUTPUT MEASUREMENTS DETERMINED BY DYE DILUTION, PULSED DOPPLER-ECHOCARDIOGRAPHY AND THERMODILUTION IN HORSES
    MIZUNO, Y
    AIDA, H
    HARA, H
    FUJINAGA, T
    HAGIO, M
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1994, 56 (01) : 1 - 5
  • [3] Performance of Electrical Velocimetry for Noninvasive Cardiac Output Measurements in Perioperative Patients After Subarachnoid Hemorrhage
    Mutoh, Tatsushi
    Sasaki, Kazumasu
    Yamamoto, Shuzo
    Yasui, Nobuyuki
    Ishikawa, Tatsuya
    Taki, Yasuyuki
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2019, 31 (04) : 422 - 427
  • [4] Noninvasive monitoring of cardiac output in critically ill patients: transesophageal Doppler vs transesophageal echocardiography
    H Quintard
    A Cariou
    K Jabbour
    S Lasocki
    P Montravers
    J Dhainaut
    J Desmonts
    Critical Care, 10 (Suppl 1):
  • [5] THE INITIAL DISTRIBUTION VOLUME OF GLUCOSE AND CARDIAC-OUTPUT AFTER HEMORRHAGE IN DOGS
    SHIMODATE, Y
    ISHIHARA, H
    MATSUKI, A
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (03): : 257 - 260
  • [6] NONINVASIVE MONITORING OF CARDIAC-OUTPUT CHANGES DURING AORTIC CROSS-CLAMPING FOR INFRARENAL RECONSTRUCTION - A NEW TECHNIQUE USING SUPRASTERNAL DOPPLER-DERIVED CARDIAC-OUTPUT
    DAVIES, JN
    RANABOLDO, CJ
    NEVIN, M
    NORMAN, J
    CROSSE, MM
    WEBSTER, JHH
    CHANT, ADB
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (05): : 467 - 470
  • [7] Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output
    van der Spoel, Anna G. E.
    Voogel, Albertus J.
    Folkers, Anja
    Boer, Christa
    Bouwman, R. Arthur
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (04) : 304 - 309
  • [8] Evaluation of the FloTrac Uncalibrated Continuous Cardiac Output System for Perioperative Hemodynamic Monitoring After Subarachnoid Hemorrhage
    Mutoh, Tatsushi
    Ishikawa, Tatsuya
    Nishino, Kyoko
    Yasui, Nobuyuki
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2009, 21 (03) : 218 - 225
  • [9] Continuous Cardiac Output and Near-Infrared Spectroscopy Monitoring to Assist in Management of Symptomatic Cerebral Vasospasm After Subarachnoid Hemorrhage
    Tatsushi Mutoh
    Tatsuya Ishikawa
    Akifumi Suzuki
    Nobuyuki Yasui
    Neurocritical Care, 2010, 13 : 331 - 338
  • [10] Continuous Cardiac Output and Near-Infrared Spectroscopy Monitoring to Assist in Management of Symptomatic Cerebral Vasospasm After Subarachnoid Hemorrhage
    Mutoh, Tatsushi
    Ishikawa, Tatsuya
    Suzuki, Akifumi
    Yasui, Nobuyuki
    NEUROCRITICAL CARE, 2010, 13 (03) : 331 - 338