BIOCORROSION STUDY OF TITANIUM-COBALT ALLOYS

被引:6
作者
LIN, JHC
LO, SJ
JU, CP
机构
[1] Department of Materials Science and Engineering, National Cheng-Kung University, Tainan
关键词
D O I
10.1111/j.1365-2842.1995.tb00781.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The present work provides experimental results of corrosion behaviour in Hank's physiological solution and some other properties of in-house fabricated titanium-cobalt alloys with cobalt ranging from 25-30% in weight. X-ray diffraction (XRD) shows that, in water-quenched (WQ) alloys, beta-titanium is largely retained, whereas in furnacecooled (FC) alloys, little beta-titanium is found. Hardness of the alloys increases with increasing cobalt content, ranging from 455 VHN for WQ Ti-25 wt% Co to 525 VHN for WQ Ti-30 wt% Co. Differential thermal analysis (DTA) indicates that melting temperatures of the alloys are lower than that of pure titanium by about 600 degrees C. Potentiodynamic polarization results show that all measured breakdown potentials in Hank's solution at 37 degrees C are higher than 800 mV. The breakdown potential for the FC Ti-25 Wt% Co alloy is even as high as nearly 1200 mV.
引用
收藏
页码:331 / 335
页数:5
相关论文
共 9 条
[1]  
CHERN LJH, 1990, J ORAL REHABIL, V17, P383
[2]  
COMBE EC, 1992, NOTES DENTAL MATERIA, P64
[3]  
HANSEN M, 1958, CONSTITUTION BINARY, P512
[4]  
Ida K, 1982, Dent Mater J, V1, P8
[5]  
Ito M, 1990, Kokubyo Gakkai Zasshi, V57, P146
[6]  
MEARS DC, 1977, INT METALS REV, V22, P119, DOI DOI 10.1179/IMTR.1977.22.1.119
[7]  
Moser J B, 1985, Dent Mater, V1, P37, DOI 10.1016/S0109-5641(85)80021-X
[8]  
Park JB., 1984, BIOMATERIALS SCI ENG, P193, DOI DOI 10.1007/978-1-4613-2769-18
[9]   CASTING PURE TITANIUM INTO COMMERCIAL PHOSPHATE-BONDED SIO2 INVESTMENT MOLDS [J].
TAKAHASHI, J ;
KIMURA, H ;
LAUTENSCHLAGER, EP ;
LIN, JHC ;
MOSER, JB ;
GREENER, EH .
JOURNAL OF DENTAL RESEARCH, 1990, 69 (12) :1800-1805