COLD-EXTRUSION DEFORMATION OF UHMWPE IN TOTAL KNEE REPLACEMENT PROSTHESES

被引:18
作者
CHANG, DCM [1 ]
GOH, JCH [1 ]
TEOH, SH [1 ]
BOSE, K [1 ]
机构
[1] NATL UNIV SINGAPORE HOSP, DEPT MECH & PROD ENGN, SINGAPORE 0511, SINGAPORE
关键词
FEM ANALYSIS; COLD EXTRUSION; ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE; TOTAL KNEE REPLACEMENT PROSTHESES;
D O I
10.1016/0142-9612(95)92120-U
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of metal-backed tibial plates in total knee replacement prostheses can result in the flow of ultra-high molecular weight polyethylene (UHMWPE) from the tibial insert into a cavity on the metal tray surface. A study of the relationship between the thickness of UHMWPE inserts and the amount of cold extrusion is reported here. An attempt was made to correlate the occurrence of cold extrusion with computer-aided analysis. UHMWPE samples of varying thickness, from 3 mm to 10mm, were placed over cobalt-chrome (Co-Cr) discs. The Co-Gr discs had a 5 mm diameter hole placed central ly to simulate a tibial tray cavity. A cyclic load was applied at 20 Hz through a Co-Cr spherical indentor for a million cycles. The application of cyclic loading on UHMWPE samples resulted in cold-extrusion values comparable to those reported for retrieval analysis studies. Results after fatigue loading show that the samples do not suffer any gross surface damage. A shiny depression was visible at the load application site and the surface roughness value was decreased. The amount of cold extrusion increased with decreasing UHMWPE sample thickness. From the results, a minimum UHMWPE thickness of 12 mm is required if cold extrusion of UHMWPE is to be eliminated.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 17 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[3]  
BLOEBAUM RD, 1991, CLIN ORTHOP RELAT R, V269, P120
[4]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[5]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[6]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, V273, P232
[8]   POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[9]   POLYETHYLENE WEAR IN UNCEMENTED KNEE REPLACEMENTS [J].
JONES, SMG ;
PINDER, IM ;
MORAN, CG ;
MALCOLM, AJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :18-22
[10]  
KILGUS DJ, 1991, CLIN ORTHOP RELAT R, V273, P223