LOW-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRY FOR THE DETECTION OF HALOGENATED GAS-CHROMATOGRAPHIC EFFLUENTS

被引:41
作者
CREED, JT [1 ]
DAVIDSON, TM [1 ]
SHEN, WL [1 ]
CARUSO, JA [1 ]
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
关键词
Chromatographic detection; Halogenated hydrocarbon detection; Low-pressure microwave-induced plasma mass spectrometry; Low-pressure plasma ion source;
D O I
10.1039/ja9900500109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-pressure helium microwave-induced plasma was interfaced to a mass spectrometer and the system was utilised as a detector for gas chromatography. The over-all system was optimised with respect to microwave power and the first-stage pressure of the mass spectrometer. The linear dynamic range for iodobenzene extended over three orders of magnitude starting at 1 pg. The absolute 3σ detection limit for iodine was 0.1 pg. The evaluation of the interface for the detection of bromine indicated an interference at mass 79 due to the formation of a polyatomic nickel species. A preliminary detection limit of 3.5 pg was calculated for bromine. A second interface design was used in a preliminary investigation of the backgrounds at masses 35 and 37. The background 35/37 ratio was correct, indicating a source of chlorine within the system. The detection limit for chlorine was 24 pg.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 15 条
[1]   APPLICATION OF HELIUM MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRY TO THE DETECTION OF HIGH IONIZATION-POTENTIAL GAS-PHASE SPECIES [J].
BROWN, PG ;
DAVIDSON, TM ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :763-769
[2]   INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL ANALYSIS AND ISOTOPE RATIO DETERMINATIONS IN INDIVIDUAL ORGANIC-COMPOUNDS SEPARATED BY GAS-CHROMATOGRAPHY [J].
CHONG, NS ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1987, 41 (01) :66-74
[3]   HELIUM SOURCE MICROWAVE-INDUCED PLASMA MASS-SPECTROMETRIC DETECTION IN THE ANALYSIS OF GAS-CHROMATOGRAPHIC ELUATES [J].
CREED, JT ;
MOHAMAD, AH ;
DAVIDSON, TM ;
ATAMAN, G ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :923-926
[4]   HELIUM MICROWAVE INDUCED PLASMA MASS-SPECTROMETRY FOR DETECTION OF METALS AND NONMETALS IN AQUEOUS-SOLUTIONS [J].
CREED, JT ;
DAVIDSON, TM ;
SHEN, WL ;
BROWN, PG ;
CARUSO, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (09) :909-924
[5]   APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE SIMULTANEOUS DETERMINATION OF CHLORINE, BROMINE AND IODINE IN THE NATIONAL-BUREAU-OF-STANDARDS STANDARD REFERENCE MATERIAL-1648 URBAN PARTICULATE [J].
DATE, AR ;
STUART, ME .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :659-665
[6]  
HEITKEMPER D, IN PRESS J CHROMATOG
[7]   ANALYSIS OF SOLUTIONS CONTAINING HIGH-LEVELS OF DISSOLVED SOLIDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :547-550
[8]   DEVELOPMENT AND ASSESSMENT OF A HELIUM INDUCTIVELY COUPLED PLASMA IONIZATION SOURCE FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KOPPENAAL, DW ;
QUINTON, LF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :667-672
[9]   EVALUATION OF INDUCTIVELY COUPLED ARGON PLASMA MASS-SPECTROMETRY (ICP-MS) FOR SIMULTANEOUS MULTI-ELEMENT TRACE ANALYSIS IN CLINICAL-CHEMISTRY [J].
LYON, TDB ;
FELL, GS ;
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :265-271
[10]  
MACLEOD SK, 1985, THESIS COLORADO STAT