FLUIDIZED-BED GAS DISTRIBUTORS

被引:38
作者
QURESHI, AE [1 ]
CREASY, DE [1 ]
机构
[1] UNIV ASTON,DEPT CHEM ENGN,BIRMINGHAM B4 7ET,W MIDLANDS,ENGLAND
关键词
D O I
10.1016/0032-5910(79)85013-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The literature on gas distributors for gas fluidised beds is reviewed from the point of view of stable operation of the bed. An equation is suggested relating the minimum value of the ratio of the distributor pressure drop for stable operation and the bed pressure drop to the aspect ratio of the bed. This equation could be used for design purposes. © 1979.
引用
收藏
页码:113 / 119
页数:7