ARE BIOELECTRIC IMPEDANCE MEASUREMENTS VALID IN PATIENTS WITH CYSTIC-FIBROSIS

被引:25
作者
BOROWITZ, D
CONBOY, K
机构
[1] Children’s Hospital of Buffalo, State University of New York, Buffalo, NY
关键词
BIOELECTRIC IMPEDANCE; CYSTIC FIBROSIS; BODY COMPOSITION;
D O I
10.1097/00005176-199405000-00008
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
This pilot study compared the use of bioelectric impedance analysis (BIA), a rapid, portable, and painless method of measuring body composition, to isotope dilution in patients with and without cystic fibrosis (CF). Many methods exist for measuring body composition but these measures can be difficult to use in the clinical setting. BIA has been validated as a tool for nutritional assessment in healthy adults, but it must be validated in patient populations with specific disease-related nutritional problems, such as CF. Ten ambulatory patients with CF were selected along with ten controls matched for age, sex, and body mass index (BMI; wt/ht2). Total body water (TBW) was determined using isotope-ratio mass spectrometry on urine specimens before and after patients consumed 0.2 g/kg deuterium-rich water. BIA was performed using a tetrapolar technique; 500 muA of current at 50 kHz was introduced and the voltage drop measured. Seven men and three women were studied in each group. Median age was 27 (range, 18-39) and median BMI was 19.2 (range, 16.7-30.1) in CF adults. Median age was 27.5 (range, 15-43) and median BMI was 20.7 (range, 19.4-31.6) in controls. The resistance index (RI; ht2/resistance) correlated strongly with TBW in patients with CF (r = 0.88; y = 0.482x + 11.138; p < 0.05) as well as in controls (r = 0.87; y = 0.661x + 1.299; p < 0.05). We conclude that BIA is a rapid, portable, and painless method for measuring body composition that correlates well with the deuterium-dilution method. However, CF-specific regression equations will need to be developed and confidence intervals defined using large numbers of patients before this technique can be widely applied to patients with CF.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 20 条
  • [1] ELECTRICAL-IMPEDANCE IN ASSESSING HUMAN-BODY COMPOSITION - THE BIA METHOD
    ABUKHALED, M
    MCCUTCHEON, MJ
    REDDY, S
    PEARMAN, PL
    HUNTER, GR
    WEINSIER, RL
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 47 (05) : 789 - 792
  • [2] USE OF BIOELECTRICAL IMPEDANCE ANALYSIS TO MEASURE TOTAL-BODY WATER IN PATIENTS WITH CYSTIC-FIBROSIS
    AZCUE, M
    FRIED, M
    PENCHARZ, PB
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1993, 16 (04) : 440 - 445
  • [3] A COMPARISON OF SURVIVAL, GROWTH, AND PULMONARY-FUNCTION IN PATIENTS WITH CYSTIC-FIBROSIS IN BOSTON AND TORONTO
    COREY, M
    MCLAUGHLIN, FJ
    WILLIAMS, M
    LEVISON, H
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1988, 41 (06) : 583 - 591
  • [4] CORRELATION OF WHOLE-BODY IMPEDANCE WITH TOTAL BODY WATER VOLUME
    HOFFER, EC
    MEADOR, CK
    SIMPSON, DC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (04) : 531 - &
  • [5] HOLT TL, 1992, PEDIATR PULM S, V8, P304
  • [6] PHARMACOKINETICS OF ANTIMICROBIAL DRUGS IN CYSTIC-FIBROSIS - AMINOGLYCOSIDE ANTIBIOTICS
    HORREVORTS, AM
    DRIESSEN, OMJ
    MICHEL, MF
    KERREBIJN, KF
    [J]. CHEST, 1988, 94 (02) : S120 - S125
  • [7] RELIABILITY AND VALIDITY OF BIOELECTRICAL IMPEDANCE IN DETERMINING BODY-COMPOSITION
    JACKSON, AS
    POLLOCK, ML
    GRAVES, JE
    MAHAR, MT
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (02) : 529 - 534
  • [8] INCREASED BIOELECTRIC POTENTIAL DIFFERENCE ACROSS RESPIRATORY EPITHELIA IN CYSTIC-FIBROSIS
    KNOWLES, M
    GATZY, J
    BOUCHER, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (25) : 1489 - 1495
  • [9] RELATIVE UNDERWEIGHT IN CYSTIC-FIBROSIS AND ITS PROGNOSTIC VALUE
    KRAEMER, R
    RUDEBERG, A
    HADORN, B
    ROSSI, E
    [J]. ACTA PAEDIATRICA SCANDINAVICA, 1978, 67 (01): : 33 - 37
  • [10] ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS
    KUSHNER, RF
    SCHOELLER, DA
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) : 417 - 424