INTRAOCULAR-PRESSURE AFTER PERIBULBAR ANESTHESIA - IS THE HONAN BALLOON NECESSARY

被引:33
|
作者
MORGAN, JE
CHANDNA, A
机构
[1] BRISTOL EYE HOSP,BRISTOL BS1 2LX,AVON,ENGLAND
[2] ROYAL LIVERPOOL UNIV HOSP,ST PAULS EYE UNIT,LIVERPOOL,MERSEYSIDE,ENGLAND
关键词
D O I
10.1136/bjo.79.1.46
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Peribulbar anaesthetic blocks administered to 70 patients and the intraocular pressure (IOP) measured immediately before and within 1 minute of the injections. In 10 patients IOPs were recorded at 1 minute intervals for 15 minutes after injection and then compared with the IOPs recorded in 60 patients after 5 or 10 minutes of Honan balloon ocular compression. The IOP rose significantly after injection in all patient groups and in some cases this increase was marked (over 50 mm Hg in 10 patients). The IOP showed an equivalent drop after 5 or 10 minutes of ocular compression when compared with eyes that did not receive ocular compression. The Honan balloon does not appear to be necessary to reduce IOP in the 10 minutes following peribulbar injection. Furthermore, the occurrence of IOP peaks after peribulbar anaesthesia suggests that the balloon should be used with caution in eyes in which the ocular circulation may be compromised.
引用
收藏
页码:46 / 49
页数:4
相关论文
共 50 条
  • [21] Necessity of the Honan intraocular pressure reducer in cataract surgery using topical anesthesia
    Black, EH
    Cohen, KL
    Tripoli, NK
    Winslow, PA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02) : 223 - 226
  • [22] EFFECT ON THE INTRAOCULAR-PRESSURE OF HYPOTENSIVE ANESTHESIA WITH INTRAVENOUS TRIMETAPHAN
    DIAS, PLR
    ANDREW, DS
    ROMANES, GJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1982, 66 (11) : 721 - 724
  • [23] INTRAOCULAR-PRESSURE CHANGES DURING HALOTHANE AND ENFLURANE ANESTHESIA
    RUNCIMAN, JC
    BOWENWRIGHT, RM
    WELSH, NH
    DOWNING, JW
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (04) : 371 - 374
  • [24] THE INFLUENCE OF ELECTRO-STIMULATION ANESTHESIA ON THE INTRAOCULAR-PRESSURE
    ABDULLA, W
    OGGEL, K
    SCHWAB, R
    ANAESTHESIST, 1981, 30 (04): : 196 - 197
  • [25] INTRAOCULAR-PRESSURE PROFILE DURING GENERAL-ANESTHESIA
    VARGHESE, C
    CHOPRA, SK
    DANIEL, R
    KAUR, B
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (12): : 856 - 859
  • [26] THE EFFECT OF DIFFERENT METHODS OF INDUCING ANESTHESIA ON INTRAOCULAR-PRESSURE
    BADRINATH, SK
    VAZEERY, A
    MCCARTHY, RJ
    IVANKOVICH, AD
    ANESTHESIOLOGY, 1986, 65 (04) : 431 - 435
  • [27] INTRAOCULAR-PRESSURE CHANGES DURING ANESTHESIA FOR ELECTROSHOCK THERAPY
    EPSTEIN, HM
    FAGMAN, W
    BRUCE, DL
    ABRAM, A
    ANESTHESIA AND ANALGESIA, 1975, 54 (04) : 479 - 481
  • [28] INFLUENCE OF TOPICAL ANESTHESIA ON TONOMETRIC VALUES OF INTRAOCULAR-PRESSURE
    BAUDOUIN, C
    GASTAUD, P
    OPHTHALMOLOGICA, 1994, 208 (06) : 309 - 313
  • [29] MEASUREMENT OF INTRAOCULAR-PRESSURE AFTER EPIKERATOPHAKIA
    OLSON, PF
    MCDONALD, MB
    WERBLIN, TP
    KAUFMAN, HE
    ARCHIVES OF OPHTHALMOLOGY, 1983, 101 (07) : 1111 - 1112
  • [30] INTRAOCULAR-PRESSURE RISE AFTER IRIDOTOMY
    ROBIN, AL
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (08) : 1117 - 1117