SYSTEM COOLING DESIGN FOR THE WATER-COOLED IBM ENTERPRISE SYSTEM/9000 PROCESSORS

被引:11
|
作者
DELIA, DJ
GILGERT, TC
GRAHAM, NH
HWANG, U
ING, PW
KAN, JC
KEMINK, RG
MALING, GC
MARTIN, RF
MORAN, KP
REYES, JR
SCHMIDT, RR
STEINBRECHER, RA
机构
关键词
D O I
10.1147/rd.364.0791
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The high operating speed and corresponding high chip heat fluxes in the IBM Enterprise System/9000(TM) water-cooled mainframe processors are made possible by improvements in component- and system-level cooling. The heart of the closed-loop water-cooling system is a coolant distribution frame (CDF) common to all water-cooled processors. The CDF provides a controlled water temperature of 21.7-degrees-C to the central electronic complex (CEC) at water flow rates up to 245 liters per minute (Ipm) and rejects heat loads of up to 63 kW for the largest processor. The water flow provides cooling to multichip thermal conduction modules (TCMs), to power supplies, and to air-to-water heat exchangers that provide preconditioned air to channel and memory cards. As many as 121 chips are mounted on a TCM glass-ceramic substrate, with chip powers reaching 27 W or a heat flux of 64 W/cm2. A separable cold plate was developed to cool these modules. The power supplies with high heat densities are primarily cooled by water which flows through a unique separable cold plate designed for ease of serviceability of the power supply. Although water cooling is utilized for components with high heat fluxes, air cooling is employed for elements of the system with lower power densities. For cards cooled by forced air, careful trade-off studies among acoustical power, chip reliability, and high availability were required. The acoustic noise emissions of all the fans and blowers were determined, and a system model was constructed to measure the noise radiated from each frame in the system. The data were used to design top covers and other components to ensure that the system could meet its thermal/acoustical requirements. A closed-loop frame in which all the heat was rejected to water was developed to meet these requirements.
引用
收藏
页码:791 / 803
页数:13
相关论文
共 50 条
  • [21] PHYSICAL AND ELECTRICAL DESIGN-FEATURES OF THE IBM ENTERPRISE SYSTEM 9000 CIRCUIT MODULE
    DAVIDSON, EE
    HARDIN, PW
    KATOPIS, GA
    NEALON, MG
    WU, LL
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1992, 36 (05) : 877 - 888
  • [23] The control system for water-cooled DCMS in SSRF
    贾文红
    马世伟
    郑丽芳
    NuclearScienceandTechniques, 2015, 26 (02) : 26 - 30
  • [24] The control system for water-cooled DCMS in SSRF
    Jia Wen-Hong
    Ma Shi-Wei
    Zheng Li-Fang
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (02)
  • [25] Effects of different water-cooled heat sinks on the cooling system performance in a data center
    He, Wei
    Zhang, Jifang
    Li, Hailong
    Guo, Rui
    Liu, Shengchun
    Wu, Xiaohui
    Wei, Jie
    Wang, Yulin
    ENERGY AND BUILDINGS, 2023, 292
  • [26] A WATER-COOLED MIRROR SYSTEM FOR SYNCHROTRON RADIATION
    DIGENNARO, R
    GEE, B
    GUIGLI, J
    HOGREFE, H
    HOWELLS, M
    RARBACK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 498 - 506
  • [27] WATER-COOLED INLET SYSTEM FOR GAS CHROMATOGRAPHS
    VANRENSBURG, JF
    MOUTON, PL
    PRETORIU.V
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1972, 10 (09) : 580 - +
  • [29] DESIGN AND PERFORMANCE OF THE IBM ENTERPRISE SYSTEM-9000 TYPE-9121 VECTOR FACILITY
    SLEGEL, TJ
    VERACCA, RJ
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1991, 35 (03) : 367 - 381
  • [30] IBM ENTERPRISE SYSTEM-9000 TYPE-9121 MODEL 320 AIR-COOLED PROCESSOR TECHNOLOGY
    GANI, VL
    GRAF, MC
    RIZZOLO, RF
    WASHBURN, WF
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1991, 35 (03) : 342 - 351