OCULAR HAZARD OF METALLIC FRAGMENTS DURING MR IMAGING AT 0.06 T

被引:13
|
作者
KELSEY, CA
KING, JN
KECK, GM
CHIU, MT
WOLFE, DM
ORRISON, WW
机构
[1] UNIV NEW MEXICO,SCH MED,DEPT NEUROL,ALBUQUERQUE,NM 87131
[2] UNIV NEW MEXICO,SCH MED,DEPT PHYS & ASTRON,ALBUQUERQUE,NM 87131
[3] EYE ASSOC NEW MEXICO,ALBUQUERQUE,NM
[4] UNIV NEW MEXICO HOSP,OPHTHALMOL CLIN,ALBUQUERQUE,NM
关键词
EYE; MR STUDIES; FOREIGN BODIES; MAGNETIC RESONANCE (MR); SAFETY;
D O I
10.1148/radiology.180.1.2052711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hazard of magnetic resonance (MR) imaging at low field strength (0.06 T) was examined by using both in vitro and in vivo animal experiments. Ferromagnetic fragments, 0.25-2.2 mm in diameter, were placed in vitreous humor obtained from excised cow eyes and in rabbit eyes. The magnetic field strength at which motion occurred was measured for each fragment size. Two types of motion, rotation and translation, were observed. The authors found that fragments that could not be seen on plain radiographs did not appear to move enough to be a significant ocular hazard during MR imaging at a field strength of 0.06 T.
引用
收藏
页码:282 / 283
页数:2
相关论文
共 50 条
  • [41] Feasibility of MR imaging-guided breast lumpectomy for malignant tumors in a 0.5-T open-configuration MR imaging system
    Hirose, M
    Kacher, DF
    Smith, DN
    Kaelin, CM
    Jolesz, FA
    ACADEMIC RADIOLOGY, 2002, 9 (08) : 933 - 941
  • [42] Time-of-flight MR angiography: Comparison of 3.0-T imaging and 1.5-T imaging - Initial experience
    Willinek, WA
    Born, M
    Simon, B
    Tschampa, HJ
    Krautmacher, C
    Gieseke, J
    Urbach, H
    Textor, HJ
    Schild, HH
    RADIOLOGY, 2003, 229 (03) : 913 - 920
  • [43] Breast lesions: Evaluation with dynamic contrast-enhanced T1-weighted MR imaging and with T2*-weighted first-pass perfusion MR imaging
    Kvistad, KA
    Rydland, J
    Vainio, J
    Smethurst, HB
    Lundgren, S
    Fjosne, HE
    Haraldseth, O
    RADIOLOGY, 2000, 216 (02) : 545 - 553
  • [44] Potential heating effect in the gravid uterus during MR HASTE imaging
    Levine, D
    Zuo, C
    Faro, CB
    Chen, Q
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 856 - 861
  • [45] MR Imaging during Endovascular Procedures: An Evaluation of the Potential for Catheter Heating
    Martin, Alastair J.
    Baek, Bryant
    Acevedo-Bolton, Gabriel
    Higashida, Randall T.
    Comstock, John
    Saloner, David A.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 45 - 53
  • [46] Diffusion-tensor MR imaging at 1.5 and 3.0 T: Initial observations
    Hunsche, S
    Moseley, ME
    Stoeter, P
    Hedehus, M
    RADIOLOGY, 2001, 221 (02) : 550 - 556
  • [47] MR imaging contrast in human brain tissue: Assessment and optimization at 4 T
    Duewell, S
    Wolff, SD
    Wen, H
    Balaban, RS
    Jezzard, P
    RADIOLOGY, 1996, 199 (03) : 780 - 786
  • [48] MR IMAGING OF NORMAL RAT-BRAIN AT 0.35 T AND CORRELATED HISTOLOGY
    FIEL, RJ
    ALLETTO, JJ
    SEVERIN, CM
    NICKERSON, PA
    ACARA, MA
    PENTNEY, RJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 651 - 656
  • [49] Dynamic contrast-enhanced MR imaging and MR-guided bone biopsy on a 0.23 T open imager
    Parkkola, RK
    Mattila, KT
    Heikkilä, JT
    Ekfors, TO
    Kallajoki, MA
    Komu, MES
    Vaara, TJ
    Aro, HT
    SKELETAL RADIOLOGY, 2001, 30 (11) : 620 - 624
  • [50] PANCREATIC DISEASE - PROSPECTIVE COMPARISON OF CT, ERCP, AND 1.5-T MR IMAGING WITH DYNAMIC GADOLINIUM ENHANCEMENT AND FAT SUPPRESSION
    SEMELKA, RC
    KROEKER, MA
    SHOENUT, JP
    KROEKER, R
    YAFFE, CS
    MICFLIKIER, AB
    RADIOLOGY, 1991, 181 (03) : 785 - 791