OCULAR HAZARD OF METALLIC FRAGMENTS DURING MR IMAGING AT 0.06 T

被引:13
|
作者
KELSEY, CA
KING, JN
KECK, GM
CHIU, MT
WOLFE, DM
ORRISON, WW
机构
[1] UNIV NEW MEXICO,SCH MED,DEPT NEUROL,ALBUQUERQUE,NM 87131
[2] UNIV NEW MEXICO,SCH MED,DEPT PHYS & ASTRON,ALBUQUERQUE,NM 87131
[3] EYE ASSOC NEW MEXICO,ALBUQUERQUE,NM
[4] UNIV NEW MEXICO HOSP,OPHTHALMOL CLIN,ALBUQUERQUE,NM
关键词
EYE; MR STUDIES; FOREIGN BODIES; MAGNETIC RESONANCE (MR); SAFETY;
D O I
10.1148/radiology.180.1.2052711
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The hazard of magnetic resonance (MR) imaging at low field strength (0.06 T) was examined by using both in vitro and in vivo animal experiments. Ferromagnetic fragments, 0.25-2.2 mm in diameter, were placed in vitreous humor obtained from excised cow eyes and in rabbit eyes. The magnetic field strength at which motion occurred was measured for each fragment size. Two types of motion, rotation and translation, were observed. The authors found that fragments that could not be seen on plain radiographs did not appear to move enough to be a significant ocular hazard during MR imaging at a field strength of 0.06 T.
引用
收藏
页码:282 / 283
页数:2
相关论文
共 50 条
  • [31] TISSUE CHARACTERIZATION OF INTRACRANIAL TUMORS BY MR IMAGING - INVIVO EVALUATION OF T1-RELAXATION AND T2-RELAXATION BEHAVIOR AT 1.5 T
    KJAER, L
    THOMSEN, C
    GJERRIS, F
    MOSDAL, B
    HENRIKSEN, O
    ACTA RADIOLOGICA, 1991, 32 (06) : 498 - 504
  • [32] Metallic renal artery MR imaging stent:: Artifact-free lumen visualization with projection and standard renal MR angiography
    Spuentrup, E
    Ruebben, A
    Stuber, M
    Günther, RW
    Buecker, A
    RADIOLOGY, 2003, 227 (03) : 897 - 902
  • [33] SMALL HEPATOCELLULAR-CARCINOMA VERSUS SMALL CAVERNOUS HEMANGIOMA - DIFFERENTIATION WITH MR IMAGING AT 2.0 T
    CHOI, BI
    HAN, MC
    KIM, CW
    RADIOLOGY, 1990, 176 (01) : 103 - 106
  • [34] MR IMAGING OF THE VOCAL-TRACT DURING VOWEL PRODUCTION
    LAKSHMINARAYANAN, AV
    LEE, S
    MCCUTCHEON, MJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01): : 71 - 76
  • [35] Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography
    Seneterre, E
    Taourel, P
    Bouvier, Y
    Pradel, J
    VanBeers, B
    Daures, JP
    Pringot, J
    Mathieu, D
    Bruel, JM
    RADIOLOGY, 1996, 200 (03) : 785 - 792
  • [36] EFFECTS RELATED TO TEMPERATURE-CHANGES DURING MR IMAGING
    PANYCH, LP
    HROVAT, MI
    BLEIER, AR
    JOLESZ, FA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (01): : 69 - 74
  • [37] Normal and transplanted rat kidneys: Diffusion MR imaging at 7 T
    Yang, DW
    Ye, Q
    Williams, DS
    Hitchens, TK
    Ho, C
    RADIOLOGY, 2004, 231 (03) : 702 - 709
  • [38] Inversion recovery versus T2-weighted sagittal MR imaging in cervical spinal cord injury
    Killeen K.L.
    Shanmuganathan K.
    Lefkowitz D.
    Mirvis S.E.
    Owens E.
    Emergency Radiology, 2001, 8 (1) : 15 - 19
  • [39] RAPID 3-DIMENSIONAL T1-WEIGHTED MR IMAGING WITH THE MP-RAGE SEQUENCE
    MUGLER, JP
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05): : 561 - 567
  • [40] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    RADIOLOGY, 1996, 200 (02) : 459 - 464