The hazard of magnetic resonance (MR) imaging at low field strength (0.06 T) was examined by using both in vitro and in vivo animal experiments. Ferromagnetic fragments, 0.25-2.2 mm in diameter, were placed in vitreous humor obtained from excised cow eyes and in rabbit eyes. The magnetic field strength at which motion occurred was measured for each fragment size. Two types of motion, rotation and translation, were observed. The authors found that fragments that could not be seen on plain radiographs did not appear to move enough to be a significant ocular hazard during MR imaging at a field strength of 0.06 T.
引用
收藏
页码:282 / 283
页数:2
相关论文
共 50 条
  • [21] Quantitative MR imaging assessment of prostate gland deformation before and during MR imaging-guided brachytherapy
    Hirose, M
    Bharatha, A
    Hata, N
    Zou, KH
    Warfield, SK
    Cormack, RA
    D'Amico, A
    Kikinis, R
    Jolesz, FA
    Tempany, CMC
    ACADEMIC RADIOLOGY, 2002, 9 (08) : 906 - 912
  • [22] PATELLOFEMORAL JOINT - EVALUATION DURING ACTIVE FLEXION WITH ULTRAFAST SPOILED GRASS MR IMAGING
    SHELLOCK, FG
    FOO, TKF
    DEUTSCH, AL
    MINK, JH
    RADIOLOGY, 1991, 180 (02) : 581 - 585
  • [23] SEDATION, ANESTHESIA, AND PHYSIOLOGICAL MONITORING DURING MR-IMAGING - EVALUATION OF PROCEDURES AND EQUIPMENT
    HOLSHOUSER, BA
    HINSHAW, DB
    SHELLOCK, FG
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 553 - 558
  • [24] T2-WEIGHTED 3-DIMENSIONAL MP-RAGE MR IMAGING
    MUGLER, JP
    SPRAGGINS, TA
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 731 - 737
  • [25] MR imaging and cardiac pacemakers:: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    Sommer, T
    Vahlhaus, C
    Lauck, G
    Von Smekal, A
    Reinke, M
    Hofer, U
    Block, W
    Träber, F
    Schneider, C
    Gieseke, J
    Jung, W
    Schild, H
    RADIOLOGY, 2000, 215 (03) : 869 - 879
  • [26] MR IMAGING OF PATELLAR CARTILAGE DEGENERATION AT 0.02-T - STUDY OF 23 CADAVERIC PATELLAE
    KOSKINEN, SK
    KOMU, M
    AHO, HJ
    KORMANO, M
    ACTA RADIOLOGICA, 1991, 32 (06) : 514 - 517
  • [27] Mechanisms and prevention of thermal injury from gamma radiosurgery headframes during 3T MR imaging
    Bennett, Marcus C.
    Wiant, David B.
    Gersh, Jacob A.
    Dolesh, Wendy
    Ding, X.
    Best, Ryan C. M.
    Bourland, J. D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (04): : 54 - 70
  • [28] MR IMAGING AND METALLIC IMPLANTS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - ASSESSMENT OF FERROMAGNETISM AND ARTIFACT
    SHELLOCK, FG
    MINK, JH
    CURTIN, S
    FRIEDMAN, MJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 225 - 228
  • [29] T1ρ MR Imaging of the human wrist in vivo
    Akella, SVS
    Regatte, RR
    Borthakur, A
    Kneeland, JB
    Leigh, JS
    Reddy, R
    ACADEMIC RADIOLOGY, 2003, 10 (06) : 614 - 619
  • [30] MR IMAGING OF LIVER METASTASES AT 1.5 T - SIMILAR CONTRAST DISCRIMINATION WITH T1-AND T2-WEIGHTED PULSE SEQUENCES
    SAINI, S
    LI, W
    WALLNER, B
    HAHN, PF
    EDELMAN, RR
    RADIOLOGY, 1991, 181 (02) : 449 - 453