Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
    Mishra, Ratish Kumar
    Sharma, Bhagwati Prasad
    Kumar, Amit
    Sherawat, Rohit
    CHINESE JOURNAL OF TRAUMATOLOGY, 2021, 24 (05) : 301 - 305
  • [42] A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures
    Liporace, FA
    Gupta, S
    Jeong, GK
    Stracher, M
    Kummer, F
    Egol, KA
    Koval, KJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) : 187 - 191
  • [43] Outcomes of distal ulna locking plate in management of unstable distal ulna fractures: a prospective case series
    Stock, K.
    Benedikt, S.
    Kastenberger, T.
    Kaiser, P.
    Arora, R.
    Zelger, P.
    Pallua, J. D.
    Schmidle, G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3137 - 3144
  • [44] Distal radius fractures-Design of locking mechanism in plate system and recent surgical procedures
    Inagaki, Katsunori
    Kawasaki, Keikichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (03) : 258 - 262
  • [45] Complications Following Volar Locking Plate Fixation of Distal Radius Fractures in Adults: A Systematic Review of Randomized Control Trials
    Nwosu, Chinemerem
    Rodriguez, Kaitlyn
    Zeng, Steven
    Klifto, Kevin M.
    Klifto, Christopher S.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (09): : 861 - 874
  • [46] Volar Locking Plates Versus External Fixation and Adjuvant Pin Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study
    Williksen, John H.
    Frihagen, Frede
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Husby, Torstein
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (08): : 1469 - 1476
  • [47] Volar locking plate fixation of distal radius fractures: Isokinetic assessment of the influence of an ulnar styloid process fracture on pronation-supination strength
    Daumillare, A.
    Bosch, C.
    Julia, M.
    Coulet, B.
    Mares, O.
    Chammas, M.
    HAND SURGERY & REHABILITATION, 2020, 39 (01) : 23 - 29
  • [48] Associations Between the Fracture Type and Functional Outcomes After Distal Radial Fractures Treated With a Volar Locking Plate
    Braziulis, Kestutis
    Rimdeika, Rytis
    Kregzdyte, Rima
    Tarasevicius, Sarunas
    MEDICINA-LITHUANIA, 2013, 49 (09): : 399 - 402
  • [49] Die palmare winkelstabile Plattenosteosynthese bei Extensionsfrakturen des distalen RadiusThe volar locking plate for extension fractures of the distal radius
    T. Pillukat
    R. Fuhrmann
    J. Windolf
    J. van Schoonhoven
    Operative Orthopädie und Traumatologie, 2016, 28 (1) : 47 - 64
  • [50] Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique
    Dos Remedios, C.
    Nebout, J.
    Benlarbi, H.
    Caremier, E.
    Sam-Wing, J. -F.
    Beya, R.
    CHIRURGIE DE LA MAIN, 2009, 28 (04) : 224 - 229