Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Neto, Jorge Raduan
    de Moraes, Vinicius Ynoe
    Gomes dos Santos, Joao B.
    Faloppa, Flavio
    Belloti, Joao Carlos
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [32] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Qiang Fu
    Lei Zhu
    Peng Yang
    Aimin Chen
    Indian Journal of Orthopaedics, 2018, 52 : 602 - 610
  • [33] Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
    Tarallo L.
    Mugnai R.
    Adani R.
    Catani F.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 285 - 290
  • [34] A Meta-analysis of Studies of Volar Locking Plate Fixation of Distal Radius Fractures: Conventional versus Minimally Invasive Plate Osteosynthesis
    Lee, Dong-Yeong
    Park, Young-Jin
    Park, Jin-Sung
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 208 - 219
  • [35] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Jorge Raduan Neto
    Vinicius Ynoe de Moraes
    João B Gomes dos Santos
    Flávio Faloppa
    João Carlos Belloti
    BMC Musculoskeletal Disorders, 15
  • [36] Mid-Term Results after Volar Plating of Distal Radius Fractures with a Newly Designed Locking Plate
    Wick, M.
    Wiesner, M.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (01): : 66 - 71
  • [37] Biomechanical Comparison of Fixed- versus Variable-Angle Locking Screws for Distal Humerus Comminuted Fractures
    Nourbakhsh, Ali
    Hirschfeld, Adam G.
    Dhulipala, Sravan
    Hutton, William
    Ganey, Timothy
    Lozada, Luis
    Schlatterer, Daniel
    Lourie, Gary Mark
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (03) : 302 - 308
  • [38] The results of non-surgical treatment for unstable distal radius fractures in elderly patients
    Kilic, Ayhan
    Ozkaya, Ufuk
    Kabukcuoglu, Yavuz
    Sokucu, Sami
    Basilgan, Seckin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (03) : 229 - 234
  • [39] Evaluation of early physical therapy in distal radius fractures treated with fixed-angle volar plate
    da Luz, Souza L.
    Raffone, Maisonnave A.
    de Oliveira, Kaempf R.
    Serrano, P. J. Delgado
    TRAUMA-SPAIN, 2009, 20 (01): : 29 - 37
  • [40] A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
    Mishra Ratish Kumar
    Prasad Sharma Bhagwati
    Kumar Amit
    Sherawat Rohit
    中华创伤杂志英文版, 2021, 24 (05) : 301 - 305