Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Clinical and Radiologic Outcomes of Volar Plate Fixation in AO Type C Distal Radius Fractures
    Senel, Ahmet
    Ozturkmen, Yusuf
    Akman, Yunus Emre
    Sukur, Erhan
    Unkar, Ethem Ayhan
    ISTANBUL MEDICAL JOURNAL, 2018, 19 (02): : 119 - 123
  • [22] Evaluation of Patient-Reported and Clinician-Reported Outcomes of Volar Locking Plate Fixation for Distal Radius Fractures
    Nagura, Nana
    Naito, Kiyohito
    Sugiyama, Yoichi
    Obata, Hiroyuki
    Goto, Kenji
    Kaneko, Ayaka
    Kawakita, So
    Kaneko, Kazuo
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (03) : 359 - 363
  • [23] The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures
    Vaiss, Lucile
    Ichihara, Satoshi
    Hendriks, Sarah
    Taleb, Chihab
    Liverneaux, Philippe
    Facca, Sybille
    JOURNAL OF WRIST SURGERY, 2014, 3 (04) : 245 - 249
  • [24] Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
    Shao, Jin
    Kong, De-Ce
    Yang, Tie-Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16230 - +
  • [25] The Effect of Ulnar Styloid Fractures on Patient-Rated Outcomes After Volar Locking Plating of Distal Radius Fractures
    Sammer, Douglas M.
    Shah, Hriday M.
    Shauver, Melissa J.
    Chung, Kevin C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (09): : 1595 - 1602
  • [26] Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 843 - 852
  • [27] Comparison Between External Fixators and Fixed-Angle Volar-Locking Plates in the Treatment of Distal Radius Fractures
    Agustin Jorge-Mora, Alberto
    Cecilia-Lopez, David
    Rodriguez-Vega, Victor
    Suarez-Arias, Laura
    Andres-Esteban, Eva
    Porras-Moreno, Miguel Angel
    Resines-Erasun, Carlos
    JOURNAL OF HAND AND MICROSURGERY, 2012, 4 (02) : 50 - 54
  • [28] An alternative fixation method for the treatment of unstable distal clavicle fractures: locked distal radius plate
    Daglar, Buelent
    Delialioglu, Oender M.
    Minareci, Emre
    Tasbas, Buelent A.
    Bayrakci, Kenan
    Gunel, Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 324 - 330
  • [29] Radiological analysis of acute distal radius fractures and clinical outcomes
    Herzberg, G.
    Burnier, M.
    HAND SURGERY & REHABILITATION, 2016, 35 : S15 - S23
  • [30] Volar-locking plate versus external fixator in the management of distal radius fractures: An isokinetic study
    Dundar, Abdulrahim
    Cankaya, Deniz
    Karakus, Dilek
    Tabak, Abdullah Yalcin
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (08): : 1156 - 1163