Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

被引:10
|
作者
Khatri, Kavin [1 ]
Sharma, Vijay [2 ]
Farooque, Kamran [2 ]
Tiwari, Vivek [2 ]
机构
[1] Baba Farid Univ Hlth Sci, GGS Med Coll Faridkot, Dept Orthopaed, Faridkot, India
[2] All India Inst Med Sci, Dept Orthopaed, Jai Prakash Narayan Apex Trauma Ctr, Delhi, India
关键词
Bone Plates; Radius; Volar Plate; Fracture Fixation; Internal; Injury; Wrist;
D O I
10.5812/atr.25174
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 +/- 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 +/- 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley's demerit scoring system was used to assess the final outcome. Results: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Variable-Angle Locking Screw Volar Plating of Distal Radius Fractures
    Park, Jung H.
    Hagopian, Jennifer
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 373 - +
  • [2] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [3] Radiological, Clinical, and Functional Outcomes of Combined Dorsal and Volar Locking Plate Osteosynthesis for Complex Distal Radius Fractures
    Luedi, Simona
    Kurz, Charlotte
    Deforth, Manja
    Ghafoor, Haval
    Haefeli, Mathias
    Honigmann, Philipp
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (04): : 377 - 387
  • [4] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [5] SURGICAL TREATMENT OF UNSTABLE DISTAL RADIUS FRACTURES WITH LOCKING VOLAR PLATES: COMPARISON BETWEEN RADIOGRAPHIC OUTCOMES AND FUNCTIONAL RESULTS
    Casale, V.
    Agati, G.
    Masse, A.
    Schiro, M.
    Violante, E.
    Drogo, N.
    D'amelio, A.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2013, 64 (03) : 293 - 303
  • [6] Complication Rate Comparing Variable Angle Distal Locking Plate to Fixed Angle Plate Fixation of Distal Radius Fractures
    Mehrzad, Raman
    Kim, David C.
    ANNALS OF PLASTIC SURGERY, 2016, 77 (06) : 623 - 625
  • [7] Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
    Calbiyik, Murat
    Ipek, Deniz
    MEDICAL SCIENCE MONITOR, 2018, 24 : 602 - 613
  • [8] Volar Plate-Suture Fixation in the Treatment of Volar Rim Fractures of the Distal Radius
    Carney, John
    Bigach, Stephen
    Goedderz, Cody
    Gerlach, Erik
    Marx, Jeremy
    Kalainov, David
    JOURNAL OF WRIST SURGERY, 2025, 14 (01) : 57 - 62
  • [9] Volar fixed plating of distal radius fractures: optimizing plate position for enhanced clinical outcomes
    Emet, Abdulsamet
    Veizi, Enejd
    Karaman, Yavuz
    Akgun, Erkan
    Tolunay, Tolga
    Firat, Ahmet
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [10] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (12) : 1773 - 1782