In-beam background suppression shield

被引:2
|
作者
Santoro, V. [1 ]
Cai, X. X. [1 ,2 ]
DiJulio, D. D. [1 ,3 ]
Ansell, S. [1 ]
Bentley, P. M. [1 ,4 ]
机构
[1] European Spallat Source ERIC, SE-22100 Lund, Sweden
[2] Tech Univ Denmark, DTU Nutech, Roskilde, Denmark
[3] Lund Univ, Dept Phys, SE-22100 Lund, Sweden
[4] Uppsala Univ, Dept Phys & Astron, S-75105 Uppsala, Sweden
关键词
Instrument backgrounds; sapphire; filter; neutrons; spallation source;
D O I
10.3233/JNR-160034
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The long (3 ms) proton pulse of the European Spallation Source (ESS) gives rise to unique and potentially high backgrounds for the instrument suite. In such a source an instrument's capabilities will be limited by its Signal to Noise (S/N) ratio. The instruments with a direct view of the moderator, which do not use a bender to help mitigate the fast neutron background, are the most challenging. For these beam lines we propose the innovative shielding of placing blocks of material directly into the guide system, which allow a minimum attenuation of the cold and thermal fluxes relative to the background suppression. This shielding configuration has been worked into a beam line model using Geant4. We study particularly the advantages of single crystal sapphire and silicon blocks.
引用
收藏
页码:135 / 144
页数:10
相关论文
共 50 条
  • [1] Suppression of random coincidences during in-beam PET measurements
    Crespo, P
    Barthel, T
    Frais-Kölbl, H
    Griesmayer, E
    Heidel, K
    Parodi, K
    Pawelke, J
    Enghardt, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2226 - 2230
  • [2] BACKGROUND SUBTRACTION FROM IN-BEAM HPGE COINCIDENCE DATA SETS
    RADFORD, DC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 361 (1-2): : 306 - 316
  • [3] IN-BEAM GE(LI)-NAI(TL) COMPTON SUPPRESSION SPECTROMETER
    BEETZ, R
    POSTHUMUS, WL
    DEBOER, FWN
    MAARLEVELD, JL
    VANDERSCHAAF, A
    KONIJN, J
    NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (02): : 353 - 357
  • [4] Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilities
    Crespo, P
    Barthel, T
    Frais-Kölbl, H
    Griesmayer, E
    Heidel, K
    Parodi, K
    Pawelke, J
    Enghardt, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 980 - 987
  • [5] COMPTON SUPPRESSION SPECTROMETER (CSS) FOR IN-BEAM GAMMA-RAY SPECTROMETRY
    IONESCU, V
    KERN, J
    NORDMANN, C
    OLBRICH, S
    RHEME, C
    NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (2-3): : 395 - 401
  • [6] BACKGROUND SUPPRESSION IN DOUBLE-BEAM INTERFEROMETRY
    ZEHNPFENNIG, TF
    SHEPHERD, O
    RAPPAPORT, S
    REIDY, WP
    VANASSE, G
    APPLIED OPTICS, 1979, 18 (12): : 1996 - 2002
  • [7] Advance in in-beam PET
    Guo Zhong-Yan
    CHINESE PHYSICS C, 2008, 32 : 214 - 216
  • [8] IN-BEAM INVESTIGATION OF TERNARY FISSION
    KOTTE, R
    FROMM, WD
    HENTSCHEL, E
    ORTLEPP, HG
    SCHILLING, KD
    SEIDEL, W
    STARY, F
    ZWICKER, G
    ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1988, 330 (02): : 189 - 195
  • [9] IN-BEAM STUDY OF AS-70
    FILEVICH, A
    BEHAR, M
    BERMUDEZ, GG
    MARISCOTTI, MAJ
    MATEOSIAN, ED
    THIEBERGER, P
    NUCLEAR PHYSICS A, 1978, 309 (1-2) : 285 - 300
  • [10] ON THE FEASIBILITY OF IN-BEAM PAC STUDIES
    IWATSCHENKOBORHO, M
    SCHMITZER, R
    HYPERFINE INTERACTIONS, 1987, 35 (1-4): : 1011 - 1014