COMPACT STAND-ALONE ATOMIC-FORCE MICROSCOPE

被引:79
作者
VANDERWERF, KO
PUTMAN, CAJ
DEGROOTH, BG
SEGERINK, FB
SCHIPPER, EH
VANHULST, NF
GREVE, J
机构
[1] Department of Applied Physics, University of Twente, 7500 AE Enschede
关键词
D O I
10.1063/1.1144378
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A stand-alone atomic force microscope (AFM) featuring large scan, friction measurement, atomic resolution, and liquid operation, has been developed. Cantilever displacements are measured using the optical beam deflection method. The laser diode and focusing lens are positioned inside the piezo tube and the cantilever at the end of the piezo tube. Because the laser beam stays on the cantilever during scanning, the scan range is solely determined by the characteristics of the piezo tube. In our case 30 x 30 x 9.5 mum3 (xyz). The optical beam deflection detection method allows simultaneous measurement of height displacements and torsion (induced by lateral forces) of the cantilever. AFM images of dried lymphocytes reveal features in the torsion images, which are only faintly visible in the normal height images. A new way of detecting the nonlinear behavior of the piezo tube is described. With this information the piezo scan is linearized. The nonlinearity in a 30-mum scan is reduced from 40% to about 1%, as is illustrated with images of a compact disk. The stand-alone AFM can be combined with a (confocal) inverted microscope, yielding a versatile setup for biological applications.
引用
收藏
页码:2892 / 2897
页数:6
相关论文
共 19 条
[1]   OPTICAL SCAN-CORRECTION SYSTEM APPLIED TO ATOMIC FORCE MICROSCOPY [J].
BARRETT, RC ;
QUATE, CF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06) :1393-1399
[2]   LATERAL FORCES DURING ATOMIC FORCE MICROSCOPY OF GRAPHITE IN AIR [J].
BASELT, DR ;
BALDESCHWIELER, JD .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (05) :2316-2322
[3]   SCANNED-CANTILEVER ATOMIC FORCE MICROSCOPE [J].
BASELT, DR ;
BALDESCHWIELER, JD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (04) :908-911
[4]   ELECTROMECHANICAL DEFLECTIONS OF PIEZOELECTRIC TUBES WITH QUARTERED ELECTRODES [J].
CHEN, CJ .
APPLIED PHYSICS LETTERS, 1992, 60 (01) :132-134
[5]   ACTIN FILAMENT DYNAMICS IN LIVING GLIAL-CELLS IMAGED BY ATOMIC FORCE MICROSCOPY [J].
HENDERSON, E ;
HAYDON, PG ;
SAKAGUCHI, DS .
SCIENCE, 1992, 257 (5078) :1944-1946
[6]   A STAND-ALONE SCANNING FORCE AND FRICTION MICROSCOPE [J].
HIPP, M ;
BIELEFELDT, H ;
COLCHERO, J ;
MARTI, O ;
MLYNEK, J .
ULTRAMICROSCOPY, 1992, 42 :1498-1503
[7]   Combined scanning force and friction microscopy of mica [J].
Marti, O. ;
Colchero, J. ;
Mlynek, J. .
Nanotechnology, 1990, 1 (02) :141-144
[8]   SIMULTANEOUS MEASUREMENT OF LATERAL AND NORMAL FORCES WITH AN OPTICAL-BEAM-DEFLECTION ATOMIC FORCE MICROSCOPE [J].
MEYER, G ;
AMER, NM .
APPLIED PHYSICS LETTERS, 1990, 57 (20) :2089-2091
[9]   CORRECTION [J].
MEYER, G .
APPLIED PHYSICS LETTERS, 1988, 53 (24) :2400-2400
[10]   FRICTION MEASUREMENTS ON PHASE-SEPARATED THIN-FILMS WITH A MODIFIED ATOMIC FORCE MICROSCOPE [J].
OVERNEY, RM ;
MEYER, E ;
FROMMER, J ;
BRODBECK, D ;
LUTHI, R ;
HOWALD, L ;
GUNTHERODT, HJ ;
FUJIHIRA, M ;
TAKANO, H ;
GOTOH, Y .
NATURE, 1992, 359 (6391) :133-135