PROTECTIVE ACTION OF METALLIC CONDUCTORS UNDER THE EFFECT OF HIGH-VOLTAGE LINES

被引:0
|
作者
RAZUMOV, LD
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As is well known, extended metallic conductors and cables are widely used both in the USSR and abroad for protecting cable communications lines (CL) from dangerous effects of high-voltage lines (HVL) and direct lightning strikes. With magnetic effects of the HVL, the protective action of conductors and cables amounts to generation of back emf in the conductors of the communications line being protected by the current induced in them. The higher the current in the support cable, the greater its protective capability. This then gives rise to the basic requirement for the protective conductors - reliable grounding. The highest protective capability, the so-called "ideal" protection coefficient (PC), is that of an "ideal" grounded support cable, i.e., a cable connected to earth by a very-low resistance. A protective cable having direct contact with the ground, without external insulation, may be considered in the majority of cases an ideally grounded cable.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [1] HIGH-VOLTAGE TRANSMISSION LINES IN TECHNOLOGY OF THE HIGH TEMPERATURE LOW SAG CONDUCTORS
    Baum, Krystyna
    RYNEK ENERGII, 2011, (03): : 94 - 98
  • [2] PROTECTIVE RELAYING FOR TAPPED HIGH-VOLTAGE TRANSMISSION-LINES
    BOZOKI, B
    BENNEY, JC
    USAS, WV
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (04): : 865 - 872
  • [3] Variations of proliferation states of cells under action of electromagnetic field of high-voltage transmission lines
    Pang Xiao-feng
    Liu lewei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1145 - 1148
  • [4] An experimental stand for investigating protective devices for high-voltage overhead lines
    A. V. Budin
    M. E. Pinchuk
    V. E. Pilschikov
    A. G. Leks
    V. V. Leont’ev
    Instruments and Experimental Techniques, 2016, 59 : 673 - 677
  • [5] An experimental stand for investigating protective devices for high-voltage overhead lines
    Budin, A. V.
    Pinchuk, M. E.
    Pilschikov, V. E.
    Leks, A. G.
    Leont'ev, V. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2016, 59 (05) : 673 - 677
  • [6] IMPACT OF HIGH-VOLTAGE LINES
    SCHERER, HN
    BULLETIN OF THE ATOMIC SCIENTISTS, 1975, 31 (07) : 51 - 52
  • [7] Ozone formation on high-voltage aerial conductors
    Boehringer, Angelika
    von Rheinbaben, Hubertus
    Roehsler, Heinz
    Stosser, Bernd
    Elektrizitatswirtschaft, 1988, 87 (21): : 1017 - 1022
  • [8] EFFECT OF HIGH-VOLTAGE LINES OF POWER TRANSMISSION ON A LOGGING CABLE
    RUVINSKII, VA
    GRIGORYAN, PM
    AKOPYAN, YV
    NEFTYANOE KHOZYAISTVO, 1979, (08): : 50 - 52
  • [9] MODIFIED EXCAVATORS PLACE PIPELINE UNDER HIGH-VOLTAGE ELECTRIC LINES
    不详
    HIGHWAY & HEAVY CONSTRUCTION, 1985, 128 (05): : 82 - 82
  • [10] Air ion concentrations under overhead high-voltage transmission lines
    Jayaratne, E. R.
    J-Fatokun, F. O.
    Morawska, L.