TIMBER FRAME CONSTRUCTION FIRE RESISTANCE EVALUTION

被引:1
|
作者
Dubravska, Katarina [1 ]
Terenova, L'udmila [1 ]
机构
[1] Tech Univ Zvolen, Fac Wood Sci & Technol, Dept Fire Protect, TG Masaryka 24, Zvolen 96053, Slovakia
来源
ACTA FACULTATIS XYLOLOGIAE ZVOLEN | 2018年 / 60卷 / 02期
关键词
fire resistance; integrity; thermal insulation; timber frame construction;
D O I
10.17423/afx.2018.60.2.16
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
In timber frame construction, a longitudinal groove with a thermal insulation is placed between two pieces of solid construction timber. In terms of fire resistance, this contact of two massive elements must meet the required criteria. The aim of this paper is to evaluate the criteria of thermal insulation and integrity of the longitudinal groove. The fire resistance, thermal insulation and integrity criteria were assessed on the basis of a medium-scale test. The theoretical approach is based on thestandard STN EN 13501-2:2016 and its follow-up standards. Some parts of the medium-scale test are different from the STN EN 1363-1 and STN 1365-1. Fire scenario of the medium-scale test is the standard time-temperature curve. Two timber frame constructions with different longitudinal groove, the longitudinal groove with polyurethane foam and the longitudinal groove with mineral wool insulation were subjected to thermal loading for 60 min. The integrity criterion was evaluated based on the visual inspection of the unexposed side of the test samples. The integrity criterion of the sample with mineral wool insulation and of the sample with polyurethane foam met the requirement for 60 min. The thermal insulation criterion was evaluated on the basis of the temperatures recorded by thermocouples. Tdhermal insulation met the requirement for 60 min.
引用
收藏
页码:161 / 175
页数:15
相关论文
共 50 条
  • [1] Fire resistance of timber decking for heavy timber construction
    Richardson, LR
    Batista, M
    FIRE AND MATERIALS, 2001, 25 (01) : 21 - 29
  • [2] Contribution to the fire resistance of timber construction using boards
    Dufkova, M.
    Kuklik, P.
    STRUCTURES AND ARCHITECTURE: CONCEPTS: APPLICATIONS AND CHALLENGES, 2013, : 2160 - 2167
  • [3] TIMBER FRAME CONSTRUCTION
    KEYWORTH, B
    JOURNAL OF THE ROYAL SOCIETY OF HEALTH, 1984, 104 (04): : 135 - 137
  • [4] Bringing fire protection to timber frame
    Anon
    Insulation, 2001, (MAY/JUNE):
  • [5] Divide of cavity in timber frame construction
    Leitnerova, Sona
    Olbrimek, Juraj
    Jankovic, Dusan
    ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 211 - 214
  • [6] Fire resistance of timber columns
    Ali, F.
    Kavanagh, S.
    Journal of the Institute of Wood Science, 2005, 17 (02): : 85 - 92
  • [7] Fire resistance of traditional timber post and beam construction - An experimental and modeling study
    Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo, 169-8555, Japan
    不详
    不详
    不详
    不详
    不详
    Struct. Fire - Proc. Int. Conf., SiF, (568-575):
  • [8] New "Fire Wall" for the Timber Construction
    不详
    BAUTECHNIK, 2018, 95 (03) : 228 - 228
  • [9] Fire resistance and burnout resistance of timber columns
    Gernay, Thomas
    FIRE SAFETY JOURNAL, 2021, 122
  • [10] Timber frame residential buildings - A problem for fire brigades?
    Laaksonen, JP
    COST ACTION E5 WORKSHOP ON FIRE SAFETY OF MEDIUM-RISE TIMBER FRAME RESIDENTIAL BUILDINGS, 1998, 179 : 32 - 33