Deep-learning-based automatic computer-aided diagnosis system for diabetic retinopathy

被引:148
作者
Mansour, Romany F. [1 ]
机构
[1] New Valley Assiut Univ, Fac Sci, Dept Math, Assiut, Egypt
关键词
Computer-aided diagnosis; Diabetic retinopathy; Deep neural network; AlexNet DNN; Convolutional neural network; Gaussian mixture model; Linear discriminant analysis; SVM;
D O I
10.1007/s13534-017-0047-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The high-pace rise in advanced computing and imaging systems has given rise to a new research dimension called computer-aided diagnosis (CAD) system for various biomedical purposes. CAD-based diabetic retinopathy (DR) can be of paramount significance to enable early disease detection and diagnosis decision. Considering the robustness of deep neural networks (DNNs) to solve highly intricate classification problems, in this paper, AlexNet DNN, which functions on the basis of convolutional neural network (CNN), has been applied to enable an optimal DR CAD solution. The DR model applies a multilevel optimization measure that incorporates pre-processing, adaptive-learning-based Gaussian mixture model (GMM)-based concept region segmentation, connected component-analysis-based region of interest (ROI) localization, AlexNet DNN-based highly dimensional feature extraction, principle component analysis (PCA)-and linear discriminant analysis (LDA)-based feature selection, and support-vector-machine-based classification to ensure optimal five-class DR classification. The simulation results with standard KAGGLE fundus datasets reveal that the proposed AlexNet DNN-based DR exhibits a better performance with LDA feature selection, where it exhibits a DR classification accuracy of 97.93% with FC7 features, whereas with PCA, it shows 95.26% accuracy. Comparative analysis with spatial invariant feature transform (SIFT) technique (accuracy-94.40%) based DR feature extraction also confirms that AlexNet DNN-based DR outperforms SIFT-based DR.
引用
收藏
页码:41 / 57
页数:17
相关论文
共 45 条
[1]   Microaneurysm detection using vessels removal and circular Hough transform [J].
Abdelazeem, S .
2002 IEEE PROCEEDINGS OF THE NINETEENTH NATIONAL RADIO SCIENCE CONFERENCE, VOLS 1 AND 2, 2002, :421-426
[2]  
Adarsh P, 2013, 2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), P206, DOI 10.1109/iccsp.2013.6577044
[3]  
Alver S, 2015, SIG PROCESS COMMUN, P1401, DOI 10.1109/SIU.2015.7130104
[4]  
[Anonymous], 1991, Ophthalmology, V98, P786
[5]   An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading [J].
Antal, Balint ;
Hajdu, Andras .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (06) :1720-1726
[6]  
Bernabeu MO, 2015, IEEE ENG MED BIO, P8070, DOI 10.1109/EMBC.2015.7320266
[7]  
Bharali P, 2015, 2015 IEEE 2ND INTERNATIONAL CONFERENCE ON RECENT TRENDS IN INFORMATION SYSTEMS (RETIS), P237, DOI 10.1109/ReTIS.2015.7232884
[8]   Detection of Diabetic Retinopathy in Retinal Images using MLP classifier [J].
Bhatkar, Amol Prataprao ;
Kharat, G. U. .
2015 IEEE International Symposium on Nanoelectronic and Information Systems, 2015, :331-335
[9]  
Du N, 2013, CHIN CONTR CONF, P3882
[10]  
Elbalaoui A, 2014, INT CONF MULTIMED, P171, DOI 10.1109/ICMCS.2014.6911368