CONSISTENCY OF CARBON-DIOXIDE REBREATHING AS A NON-INVASIVE METHOD TO DETERMINE EXERCISE CARDIAC-OUTPUT

被引:11
|
作者
KNOWLTON, RG [1 ]
ADAMS, GE [1 ]
机构
[1] SO ILLINOIS UNIV, DEPT PHYS EDUC, CARBONDALE, IL 62901 USA
关键词
D O I
10.1080/00140137408931343
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [1] ASSESSMENT OF CARDIAC-OUTPUT AT REST AND DURING EXERCISE BY A CARBON-DIOXIDE REBREATHING METHOD
    REYBROUCK, T
    FAGARD, R
    EUROPEAN HEART JOURNAL, 1990, 11 : 21 - 25
  • [2] AUTOMATED NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT - COMPARISON OF ELECTRICAL BIOIMPEDANCE AND CARBON-DIOXIDE REBREATHING TECHNIQUES
    SMITH, SA
    RUSSELL, AE
    WEST, MJ
    CHALMERS, J
    BRITISH HEART JOURNAL, 1988, 59 (03): : 292 - 298
  • [3] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY A CARBON-DIOXIDE REBREATHING METHOD AT REST AND DURING EXERCISE
    NUGENT, AM
    MCPARLAND, J
    MCENEANEY, DJ
    STEELE, I
    CAMPBELL, NPS
    STANFORD, CF
    NICHOLLS, DP
    EUROPEAN HEART JOURNAL, 1994, 15 (03) : 361 - 368
  • [4] MEASUREMENT OF CARDIAC-OUTPUT BY CARBON-DIOXIDE REBREATHING METHODS
    HEIGENHAUSER, GJF
    JONES, NL
    CLINICS IN CHEST MEDICINE, 1989, 10 (02) : 255 - 264
  • [5] DETERMINATION OF CARDIAC-OUTPUT AT REST AND DURING EXERCISE BY CARBON-DIOXIDE REBREATHING METHOD IN OBSTRUCTIVE AIRWAY DISEASE
    MAHLER, DA
    MATTHAY, RA
    SNYDER, PE
    NEFF, RK
    LOKE, J
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1985, 131 (01): : 73 - 78
  • [6] NON-INVASIVE CARDIAC-OUTPUT DETERMINATION USING INHALED OXYGEN-15-LABELED CARBON-DIOXIDE
    BRASLOW, NM
    HALES, CA
    HOOP, B
    KANAREK, DJ
    KAZEMI, H
    JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (05) : 1125 - 1132
  • [7] NON-INVASIVE METHOD FOR THE MEASUREMENT OF CARDIAC-OUTPUT
    NARUMI, J
    SUMA, K
    OHE, Y
    IWABUCHI, K
    UCHIYAMA, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 801 - 802
  • [8] AUTOMATED NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY THE CARBON-DIOXIDE REBREATHING METHOD - COMPARISONS WITH DYE DILUTION AND THERMODILUTION
    RUSSELL, AE
    SMITH, SA
    WEST, MJ
    AYLWARD, PE
    MCRITCHIE, RJ
    HASSAM, RM
    MINSON, RB
    WING, LMH
    CHALMERS, JP
    BRITISH HEART JOURNAL, 1990, 63 (03): : 195 - 199
  • [9] THE RELIABILITY OF THE CARBON-DIOXIDE REBREATHING, INDIRECT FICK METHOD OF CARDIAC-OUTPUT DETERMINATION IN PATIENTS WITH PULMONARY-DISEASE
    STEWART, RI
    LEWIS, CM
    CLINICAL SCIENCE, 1983, 64 (03) : 289 - 293
  • [10] CARDIAC-OUTPUT MEASUREMENT BY CARBON-DIOXIDE REBREATHING - REPRODUCIBILITY IN NORMAL SUBJECTS - APPLICATIONS IN CARDIAC-FAILURE
    DOUARD, H
    BLAQUIERE, C
    OYSEL, N
    ROUGIER, P
    BROUSTET, JP
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1993, 86 (03): : 341 - 347