Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study

被引:5
作者
Chopra, Sakshi [1 ]
Gupta, Narendra Kumar [1 ]
Tandan, Amrit [1 ]
Dwivedi, Ravi [1 ]
Gupta, Swati [1 ]
Agarwal, Garima [1 ]
机构
[1] BBDCODS, Dept Prosthodont, Lucknow, Uttar Pradesh, India
关键词
Impression material; pressure; pressure sensor; spacer; special tray;
D O I
10.4103/0976-237X.177108
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. Materials and Methods: The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. Results: A significant difference in the pressure produced using different impression materials was found (P < 0.001). Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. Conclusion: All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Clinical Implication: Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 25 条
[1]  
Anusavice KJ., 2003, PHILIPS SCI DENT MAT, P223
[2]   CLINICAL-EVALUATION OF POLYVINYLSILOXANE FOR COMPLETE DENTURE IMPRESSIONS [J].
APPELBAUM, EM ;
MEHRA, RV .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (04) :537-539
[3]   CLINICAL, CEPHALOMETRIC, AND DENSITOMETRIC STUDY OF REDUCTION OF RESIDUAL RIDGES [J].
ATWOOD, DA ;
COY, WA .
JOURNAL OF PROSTHETIC DENTISTRY, 1971, 26 (03) :280-&
[5]   A CRITICAL ANALYSIS OF MID-CENTURY IMPRESSION TECHNIQUES FOR FULL DENTURES [J].
BOUCHER, CO .
JOURNAL OF PROSTHETIC DENTISTRY, 1951, 1 (04) :472-491
[6]  
Buckley GA, 1955, J PROSTHET DENT, V5, P149
[7]  
De Van MM., 1935, DENT COSMOS, V77, P109
[8]   BASIC PRINCIPLES IN IMPRESSION MAKING [J].
DEVAN, MM .
JOURNAL OF PROSTHETIC DENTISTRY, 1952, 2 (01) :26-35
[9]   A selective-pressure impression technique for the edentulous maxilla [J].
Duncan, JP ;
Raghavendra, S ;
Taylor, TD .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03) :299-301
[10]   ANALYSIS OF PRESSURES PRODUCED DURING MAXILLARY EDENTULOUS IMPRESSION PROCEDURES [J].
FRANK, RP .
JOURNAL OF PROSTHETIC DENTISTRY, 1969, 22 (04) :400-&