MULTIFREQUENCY STATIC IMAGING IN ELECTRICAL-IMPEDANCE TOMOGRAPHY .1. INSTRUMENTATION REQUIREMENTS

被引:39
作者
RIU, PJ
ROSELL, J
LOZANO, A
PALLASARENY, R
机构
[1] Divisió d'Instrumentació i Bioenginyeria, Departament d'Enginyeria Electrònica, Universitat Politècnica de Catalunya, Barcelona, 08034
关键词
ELECTRICAL IMPEDANCE TOMOGRAPHY; MULTIFREQUENCY; STATIC IMAGING;
D O I
10.1007/BF02523010
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Static images of the human body using electrical impedance tomography techniques can be obtained by measuring at two or more different frequencies. The frequencies used depend on the application, and their selection depends on the frequency behaviour of the impedance for the target tissue. An analysis using available data and theoretical models for tissue impedance yields the expected impedance and boundary voltage changes, therefore setting the measurement instrument specifications. The instrument errors produced by different sources are analysed, and, from this analysis it is possible to determine the feasibility of building the instrument, the limit values for some parameters (or components) and indications on the most suitable design of critical parts. This analysis also shows what kinds of error can be expected in the reconstructed images. It is concluded that it is possible to build an instrument with limited errors, allowing static images to be obtained. An instrument has been built that meets some of the design requirements and fails in others because of technological problems. In vivo images obtained with this instrument will be presented in Part 2 of this work.
引用
收藏
页码:784 / 792
页数:9
相关论文
共 19 条
[1]  
Brown B. H., 1985, International Conference on Electric and Magnetic Fields in Medicine and Biology (Conf. Publ. No.257), P79
[2]   THE FREQUENCY-DEPENDENCE OF AN ANALYTICAL MODEL OF AN ELECTRICALLY STIMULATED BIOLOGICAL STRUCTURE [J].
DRAGO, GP ;
MARCHESI, M ;
RIDELLA, S .
BIOELECTROMAGNETICS, 1984, 5 (01) :47-62
[3]   INVIVO IMAGING OF CARDIAC RELATED IMPEDANCE CHANGES [J].
EYUBOGLU, BM ;
BROWN, BH ;
BARBER, DC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1989, 8 (01) :39-45
[4]  
FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
[5]  
Griffiths H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P103, DOI 10.1088/0143-0815/8/4A/014
[6]   DISTINGUISHABILITY OF CONDUCTIVITIES BY ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
ISAACSON, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (02) :91-95
[7]   Aspects of instrumentation design for impedance imaging [J].
Murphy, D. ;
Rolfe, P. .
Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A) :5-14
[8]  
NEWELL JC, 1992, 14TH IEEE ENG MED BI, P1752
[9]   DIELECTRIC-PROPERTIES OF BIOLOGICAL-MATERIALS - BIOPHYSICAL AND MEDICAL APPLICATIONS [J].
PETHIG, R .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1984, 19 (05) :453-474
[10]  
RAMO S, 1965, CAMPOST ONDAS