Construction and First Tests of an in-beam PET Demonstrator Dedicated to the Ballistic Control of Hadrontherapy Treatments With 65 MeV Protons

被引:11
作者
Binet, S. [1 ]
Bongrand, A. [1 ]
Busato, E. [1 ]
Force, P. [1 ]
Guicheney, C. [1 ]
Insa, C. [1 ]
Lambert, D. [1 ]
Magne, M. [1 ]
Martin, F. [1 ]
Perrin, H. [1 ]
Podlyski, F. [1 ]
Rozes, A. [1 ]
Montarou, G. [1 ]
机构
[1] Univ Clermont Auvergne, Lab Phys Clermont, CNRS, IN2P3, F-63000 Clermont Ferrand, France
关键词
beta(+) activity; hadrontherapy; in-beam PET; reconstruction algorithm;
D O I
10.1109/TRPMS.2017.2780447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The construction and first proton beam tests of a demonstrator dedicated to the beam ballistic control in hadrontherapy cancer treatments are described. This cost-effective demonstrator, called large area pixelized detector, is a PET-like detector used for in-beam ballistic control. It was built to test the feasibility of monitoring in real time, during irradiation, the ion range in the patient through the measurement of the beam-induced beta(+) activity distribution. Achieving this goal necessitates to overcome several challenges. One of them is the rejection of the beam-induced background. Another one is the definition of fast event selection and reconstruction techniques so that real time monitoring is possible. Strategies employed to tackle these problems are presented and tested with the 65 MeV Medicyc proton beam of the cancer treatment center in Nice, France. In particular, an original fast reconstruction technique is presented. First performances obtained during irradiation of polymethyl methacrylate targets are described.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 24 条
[1]  
Abellan C., 2013, P 33 INT C ADV NUCL, P1, DOI [10.1109/ANIMMA.2013.6728028, DOI 10.1109/ANIMMA.2013.6728028]
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]   ROOT - A C++ framework for petabyte data storage, statistical analysis and visualization [J].
Antcheva, I. ;
Ballintijn, M. ;
Bellenot, B. ;
Biskup, M. ;
Brun, R. ;
Buncic, N. ;
Canal, Ph. ;
Casadei, D. ;
Couet, O. ;
Fine, V. ;
Franco, L. ;
Ganis, G. ;
Gheata, A. ;
Maline, D. Gonzalez ;
Goto, M. ;
Iwaszkiewicz, J. ;
Kreshuk, A. ;
Segura, D. Marcos ;
Maunder, R. ;
Moneta, L. ;
Naumann, A. ;
Offermann, E. ;
Onuchin, V. ;
Panacek, S. ;
Rademakers, F. ;
Russo, R. ;
Tadel, M. .
COMPUTER PHYSICS COMMUNICATIONS, 2009, 180 (12) :2499-2512
[4]   Kernel estimation in high-energy physics [J].
Cranmer, K .
COMPUTER PHYSICS COMMUNICATIONS, 2001, 136 (03) :198-207
[5]   Charged hadron tumour therapy monitoring by means of PET [J].
Enghardt, W ;
Crespo, P ;
Fiedler, F ;
Hinz, R ;
Parodi, K ;
Pawelke, J ;
Pönisch, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) :284-288
[6]   Positron camera for range verification of heavy-ion radiotherapy [J].
Iseki, Y ;
Mizuno, H ;
Futami, Y ;
Tomitani, T ;
Kanai, T ;
Kanazawa, M ;
Kitagawa, A ;
Murakami, T ;
Nishio, T ;
Suda, M ;
Urakabe, E ;
Yunoki, A ;
Sakai, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03) :840-849
[7]   ACCURACY OF PROTON BEAM RANGE VERIFICATION USING POST-TREATMENT POSITRON EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY AS FUNCTION OF TREATMENT SITE [J].
Knopf, Antje-Christin ;
Parodi, Katia ;
Paganetti, Harald ;
Bortfeld, Thomas ;
Daartz, Juliane ;
Engelsman, Martijn ;
Liebsch, Norbert ;
Shih, Helen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01) :297-304
[8]  
Lestand L., 2012, THESIS
[9]   In Beam PET Acquisition on 75 MeV. u-1 Carbon Beam Using Sampling-Based Read-Out Electronics [J].
Lestand, Loic ;
Montarou, Gerard ;
Force, Paul ;
Joly, Baptiste ;
Lambert, Daniel ;
Magne, Magali ;
Martin, Franck ;
Rozes, Arnaud ;
Vert, Pierre Etienne ;
Chadelas, Robert .
IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (01) :87-95
[10]   On-line monitoring of radiotherapy beams: Experimental results with proton beams [J].
Litzenberg, DW ;
Roberts, DA ;
Lee, MY ;
Pham, K ;
Molen, AMV ;
Ronningen, R ;
Becchetti, FD .
MEDICAL PHYSICS, 1999, 26 (06) :992-1006