A Biomechanical Comparison between Taylor's Spatial Frame and Ilizarov External Fixator

被引:21
作者
Tan, B. B. [1 ]
Shanmugam, R. [1 ]
Chua, Y. P. [1 ]
Hossain, G. [1 ]
Saw, A. [1 ]
机构
[1] Univ Malaya, NOCERAL, Kuala Lumpur, Malaysia
关键词
Taylor's Spatial Frame; Ilizarov External Fixator; Biomechanical properties;
D O I
10.5704/MOJ.1407.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4 threaded rods, and 6 threaded rods were compared to a standard IEF rings with 4 threaded rods. Compression and torsional loading was performed to the frame as well as construct with Polyvinylchloride tubes. TSF rings with 4 tube connectors had the highest stiffness ( 3288 N/mm) while TSF rings with 6 struts was the least stiff. The situation was reversed for torsion where TSF rings with 6 oblique struts had the highest torsional stiffness (82.01 Nm/Degree) and frame Ilizarov rings with 4 threaded rods the least. Standard TSF construct of two ring with 6 oblique struts have better torsional stiffness and lower axial stiffness compared to the standard IEF.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 14 条
[1]   Biomechanics of olive wire positioning and tensioning characteristics [J].
Antoci, V ;
Voor, MJ ;
Antoci, V ;
Roberts, CS .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2005, 25 (06) :798-803
[2]   The effect of transfixion wire number and spacing between two levels of fixation on the stiffness of proximal tibial external fixation [J].
Antoci, V ;
Roberts, CS ;
Antoci, V ;
Voor, MJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) :180-186
[3]  
Azmi M Y Jr, 2009, Malays J Nutr, V15, P97
[4]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[5]  
FLEMING B, 1989, CLIN ORTHOP RELAT R, P95
[6]  
Fragomen Austin T, 2007, HSS J, V3, P13, DOI 10.1007/s11420-006-9025-0
[7]   Conformational Instability of the Taylor Spatial Frame A Case Report and Biomechanical Study [J].
Henderson, Eric R. ;
Feldman, David S. ;
Lusk, Craig ;
van Bosse, Harold J. ;
Sala, Debra ;
Kummer, Frederick J. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2008, 28 (04) :471-477
[8]   THE TENSION STRESS EFFECT ON THE GENESIS AND GROWTH OF TISSUES .1. THE INFLUENCE OF STABILITY OF FIXATION AND SOFT-TISSUE PRESERVATION [J].
ILIZAROV, GA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (238) :249-281
[9]  
Ismail M N, 2002, Obes Rev, V3, P203, DOI 10.1046/j.1467-789X.2002.00074.x
[10]   Comparison of transverse wires and half pins in Taylor Spatial Frame: A biomechanical study [J].
Khurana, Ashish ;
Byrne, Carlton ;
Evans, Sam ;
Tanaka, Hiro ;
Haraharan, Kartik .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5