POTENTIOMETRIC GAS SENSOR FOR CARBON-DIOXIDE USING SOLID ELECTROLYTES

被引:191
|
作者
MARUYAMA, T
SASAKI, S
SAITO, Y
机构
[1] Tokyo Inst of Technology, Yokohama, Jpn, Tokyo Inst of Technology, Yokohama, Jpn
关键词
ELECTROLYTES; SOLID - Applications - SODIUM COMPOUNDS - Ionic Conduction;
D O I
10.1016/0167-2738(87)90088-9
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Small insert-type CO//2 sensors are constructed by coating Na//2CO//3 on the one side of a tip-shaped solid electrolyte of NASICON or 'beta'-alumina, and the electromotive force (EMF) is examined at temperatures between 600 and 1000 K. The EMF depends only on the partial pressure of CO//2 and is expressed by the Nernst equation because the activity of Na//2O in the solid electrolytes remains constant. The high activity of Na//2O results in the formation of Na//2CO//3 on the other side of the solid electrolyte tip, giving the EMF to be zero. The response of the sensor is quite rapid. The hybrid CO//2-O//2 sensor is designed by joining the NASICON CO//2 sensor with a stabilized zirconia oxygen sensor. It is revealed by the EMF measurement on the hybrid sensor that the CO//2 sensor functions at oxygen partial pressures above 10** minus **4 Pa.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [21] CAPACITIVE-TYPE GAS SENSOR FOR THE SELECTIVE DETECTION OF CARBON-DIOXIDE
    ISHIHARA, T
    KOMETANI, K
    MIZUHARA, Y
    TAKITA, Y
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 470 - 472
  • [22] A CARBON-DIOXIDE GAS SENSOR PROBE BASED ON A LITHIUM IONIC CONDUCTOR
    IMANAKA, N
    KAWASATO, T
    ADACHI, GY
    CHEMISTRY LETTERS, 1990, (04) : 497 - 500
  • [23] DETERMINATION OF MICROGRAM QUANTITIES OF WATER IN ORGANIC-SOLVENTS USING A CARBON-DIOXIDE GAS SENSOR
    HASSAN, SSM
    AHMED, MA
    ANALYTICAL LETTERS, 1991, 24 (05) : 817 - 826
  • [24] SIMULTANEOUS DETERMINATION OF HYDROGEN, METHANE AND CARBON-DIOXIDE OF BREATH USING GAS-SOLID CHROMATOGRAPHY
    TSUJI, K
    SHIMIZU, M
    NISHIMURA, Y
    NAKAGAWA, Y
    ICHIKAWA, T
    JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 1992, 38 (01) : 103 - 109
  • [25] CARBON-DIOXIDE SENSOR FOR FERMENTATION SYSTEMS
    SHODA, M
    ISHIKAWA, Y
    BIOTECHNOLOGY AND BIOENGINEERING, 1981, 23 (02) : 461 - 466
  • [26] A CARBON-DIOXIDE SENSOR BASED ON FLUORESCENCE
    ZHUJUN, Z
    SEITZ, WR
    ANALYTICA CHIMICA ACTA, 1984, 160 (JUN) : 305 - 309
  • [27] PIEZOELECTRIC SENSOR FOR DISSOLVED CARBON-DIOXIDE
    FOGLEMAN, WW
    SHUMAN, MS
    ANALYTICAL LETTERS, 1976, 9 (08) : 751 - 765
  • [28] ELECTROCHEMICAL SENSOR FOR CARBON-DIOXIDE TEST
    MAGEARU, V
    DIACU, E
    LUCA, C
    REVISTA DE CHIMIE, 1987, 38 (06): : 506 - 509
  • [29] POTENTIOMETRIC MICROBIOLOGICAL ASSAY OF GENTAMICIN, STREPTOMYCIN, AND NEOMYCIN WITH A CARBON-DIOXIDE GAS-SENSING ELECTRODE
    SIMPSON, DL
    KOBOS, RK
    ANALYTICAL CHEMISTRY, 1983, 55 (12) : 1974 - 1977
  • [30] POTENTIOMETRIC GAS SENSORS BASED ON FAST SOLID ELECTROLYTES
    HOTZEL, G
    WEPPNER, W
    SENSORS AND ACTUATORS, 1987, 12 (04): : 449 - 453