POTENTIOMETRIC GAS SENSOR FOR CARBON-DIOXIDE USING SOLID ELECTROLYTES

被引:191
|
作者
MARUYAMA, T
SASAKI, S
SAITO, Y
机构
[1] Tokyo Inst of Technology, Yokohama, Jpn, Tokyo Inst of Technology, Yokohama, Jpn
关键词
ELECTROLYTES; SOLID - Applications - SODIUM COMPOUNDS - Ionic Conduction;
D O I
10.1016/0167-2738(87)90088-9
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Small insert-type CO//2 sensors are constructed by coating Na//2CO//3 on the one side of a tip-shaped solid electrolyte of NASICON or 'beta'-alumina, and the electromotive force (EMF) is examined at temperatures between 600 and 1000 K. The EMF depends only on the partial pressure of CO//2 and is expressed by the Nernst equation because the activity of Na//2O in the solid electrolytes remains constant. The high activity of Na//2O results in the formation of Na//2CO//3 on the other side of the solid electrolyte tip, giving the EMF to be zero. The response of the sensor is quite rapid. The hybrid CO//2-O//2 sensor is designed by joining the NASICON CO//2 sensor with a stabilized zirconia oxygen sensor. It is revealed by the EMF measurement on the hybrid sensor that the CO//2 sensor functions at oxygen partial pressures above 10** minus **4 Pa.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [1] POTENTIOMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    MOKHALLALATI, AO
    ISTUDOR, A
    VIRTOSU, D
    LUCA, C
    REVUE ROUMAINE DE CHIMIE, 1985, 30 (01) : 31 - 36
  • [2] CARBON-DIOXIDE SENSOR USING SOLID ELECTROLYTES WITH ZIRCONIUM-PHOSPHATE FRAMEWORK
    IKEDA, S
    KATO, S
    NOMURA, K
    ITO, K
    EINAGA, H
    SAITO, S
    FUJITA, Y
    SOLID STATE IONICS, 1994, 70 (pt 1) : 569 - 571
  • [3] A smart carbon dioxide gas sensor based on solid electrolytes
    Maekawa, T
    Kawabata, Y
    Nakazato, Y
    Ishikawa, H
    Tamura, S
    Imanaka, N
    Adachi, GY
    ELECTROCHEMISTRY, 2006, 74 (02) : 118 - 120
  • [4] FAST-RESPONDING POTENTIOMETRIC CARBON-DIOXIDE SENSOR
    TIERNEY, MJ
    KIM, HOL
    JOSEPH, J
    OTAGAWA, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 12 - ANYL
  • [5] CONDUCTIMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    HIMPLER, HA
    BRAND, SF
    BRAND, MJD
    ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1623 - 1627
  • [6] Carbon dioxide gas sensor with multivalent cation conducting solid electrolytes
    Imanaka, N
    Kamikawa, M
    Tamura, S
    Adachi, G
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) : 301 - 306
  • [7] SELECTIVITY OF THE POTENTIOMETRIC CARBON-DIOXIDE GAS-SENSING ELECTRODE
    LOPEZ, ME
    ANALYTICAL CHEMISTRY, 1984, 56 (13) : 2360 - 2366
  • [8] CARBON-DIOXIDE SENSOR USING THERMOPHILIC BACTERIA
    SUZUKI, H
    TAMIYA, E
    KARUBE, I
    OSHIMA, T
    ANALYTICAL LETTERS, 1988, 21 (08) : 1323 - 1336
  • [9] DYNAMIC-RESPONSE CHARACTERISTICS OF THE POTENTIOMETRIC CARBON-DIOXIDE SENSOR FOR THE DETERMINATION OF ASPARTAME
    NIKOLELIS, DP
    KRULL, UJ
    ANALYST, 1990, 115 (07) : 883 - 888
  • [10] THE PRESERVATIVE EFFECT OF SOLID CARBON-DIOXIDE AND CARBON-DIOXIDE GAS ON QUALITY OF SALTED AND SWEETENED BUTTER MILK
    KARUNAKAR, S
    RAO, BVR
    RAO, TJ
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 1984, 21 (01): : 46 - 48