HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MORPHINE, MORPHINE-3-GLUCURONIDE, MORPHINE-6-GLUCURONIDE AND CODEINE IN BIOLOGICAL SAMPLES USING MULTIWAVELENGTH FORWARD OPTICAL-DETECTION

被引:50
作者
CHARI, G
GULATI, A
BHAT, R
TEBBETT, IR
机构
[1] UNIV ILLINOIS,DEPT PHARMACODYNAM,833 S WOOD ST,CHICAGO,IL 60612
[2] UNIV ILLINOIS,DEPT PEDIAT,CHICAGO,IL 60612
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 571卷 / 1-2期
关键词
D O I
10.1016/0378-4347(91)80454-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An isocratic high-performance liquid chromatographic method has been developed for the determination of morphine, morphine-3-glucuronide, morphine-6-glucuronide and codeine in plasma, urine and cerebrospinal fluid. The use of an efficient solid-phase extraction procedure together with a forward optical scanning detector allows a detection limit of 500 pg/ml. The method was evaluated by examination of biological samples taken from newborn infants following the intravenous administration of morphine sulfate.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 24 条
[1]  
AHERNE GW, 1983, METHODS MORPHINE EST, P21
[2]   SIMULTANEOUS DETERMINATION OF CODEINE, NORCODEINE AND MORPHINE IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
CHEN, ZR ;
BOCHNER, F ;
SOMOGYI, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 491 (02) :367-378
[3]   DETERMINATION OF OPIATES IN BIOLOGICAL SAMPLES BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
EDLUND, PO .
JOURNAL OF CHROMATOGRAPHY, 1981, 206 (01) :109-116
[4]   ANALYSIS OF MORPHINE AND ITS MAJOR METABOLITES BY DIFFERENTIAL RADIOIMMUNOASSAY [J].
HAND, CW ;
MOORE, RA ;
MCQUAY, HJ ;
ALLEN, MC ;
SEAR, JW .
ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 :153-160
[5]  
HANKS GW, 1987, LANCET, V2, P723
[6]   AN IMPROVED METHOD FOR THE SIMULTANEOUS DETERMINATION OF MORPHINE AND ITS PRINCIPAL GLUCURONIDE METABOLITES [J].
JOEL, SP ;
OSBORNE, RJ ;
SLEVIN, ML .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (02) :394-399
[7]   METHOD FOR DETERMINATION OF MORPHINONE IN URINE AND BILE OF GUINEA-PIG BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KUMAGAI, Y ;
ISHIDA, T ;
TOKI, S .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (01) :155-160
[8]   RAPID SCREENING FOR 100 BASIC DRUGS AND METABOLITES IN URINE USING CATION-EXCHANGE SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION [J].
LOGAN, BK ;
STAFFORD, DT ;
TEBBETT, IR ;
MOORE, CM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (03) :154-159
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETECTION OF MORPHINE BY FLUORESCENCE AFTER POST-COLUMN DERIVATIZATION .2. THE EFFECT OF MICELLE FORMATION [J].
NELSON, PE .
JOURNAL OF CHROMATOGRAPHY, 1984, 298 (01) :59-65
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETECTION OF MORPHINE BY FLUORESCENCE AFTER POST-COLUMN DERIVATIZATION [J].
NELSON, PE ;
NOLAN, SL ;
BEDFORD, KR .
JOURNAL OF CHROMATOGRAPHY, 1982, 234 (02) :407-414