A comparison of i-gel (TM) and Laryngeal Mask Airway Supreme (TM) during general anesthesia in infants

被引:14
|
作者
Lee, Yoon Chan [1 ]
Yoon, Kyoung Seop [1 ]
Park, Sang Yoong [1 ]
Choi, So Ron [1 ]
Chung, Chan Jong [1 ]
机构
[1] Dong A Univ Hosp, Dept Anesthesiol & Pain Med, 26 Daesingongwon Ro, Busan 49201, South Korea
关键词
Infant; i-gel; Laryngeal masks;
D O I
10.4097/kjae.2018.71.1.37
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The i-gel (TM) (i-gel) and Laryngeal Mask Airway Supreme (TM) (LMA Supreme) have been safely used in children. We compared the airway performance of the i-gel and LMA Supreme in infants undergoing general anesthesia. Methods: Sixty infants with American Society of Anesthesiologists physical status I or II were randomly assigned to place either the i-gel or the LMA Supreme. The size 1 or 1.5 of each airway was selected by the weight of infants. The primary outcome variable was oropharyngeal leak pressure (OLP). We also assessed insertion success rate, insertion time, fiber-optic view of the larynx, airway quality, airway manipulations, and perioperative complications. Results: Demographic data did not differ between the two groups. Insertion success rate was similar in both groups. OLP for the i-gel (26.0 +/- 3.8 cmH(2)O) was higher than for the LMA Supreme (23.7 +/- 3.2 cmH2O) (P = 0.016). Insertion time for the i-gel (16.4 +/- 2.8 s) was shorter than for the LMA Supreme (18.5 +/- 2.7 s) (P = 0.002). There were no differences in fiberoptic view of the larynx, airway quality, airway manipulations, and complications between the two groups. Conclusions: This study demonstrated that the i-gel and LMA Supreme provided a similar performance of airway in infants. Compared with the LMA Supreme, the i-gel provided shorter insertion time and higher OLP in infants.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [1] Clinical Comparison of I-gel and Laryngeal Mask Airway-Supreme Airway Devices During General Anaesthesia in the Paediatric Population
    Aggarwal, Manish
    Yadav, Rahul
    Singh, Shalendra
    Bansal, Deepali
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (03) : 244 - 249
  • [2] A comparison of i-gel(TM) and LMA Supreme(TM) in anesthetized and paralyzed children
    Kim, Hyuk
    Lee, Ji Yeon
    Lee, Seung Yoon
    Park, Sang Yoong
    Lee, Seung Cheol
    Chung, Chan Jong
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (05) : 317 - 322
  • [3] Comparison of Frequency of Complications of i-Gel and Laryngeal Mask Airway Supreme™ in Laparoscopic Cholecystectomy
    Ali, Kashif
    Kumar, Ravi
    Ali, Abid
    Ali, Pervaiz
    Alam, M. Aneeque
    Kumar, Kelash
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (12): : 3180 - 3182
  • [4] Clinical Performance of I-gel® and BlockBuster™ Laryngeal Mask Airway in Adult Patients during General Anesthesia: A Randomized Comparison
    Das, Prerna Prabhat
    Tiwari, Tanmay
    Raman, Rajesh
    Gautam, Shefali
    Kushwaha, B. B.
    Kumar, Yatendra
    INTERNATIONAL JOURNAL OF APPLIED AND BASIC MEDICAL RESEARCH, 2024, 14 (02) : 108 - 113
  • [5] A randomised trial to compare i-gel and ProSeal (TM) laryngeal mask airway for airway management in paediatric patients
    Nirupa, R.
    Gombar, Satinder
    Ahuja, Vanita
    Sharma, Preeti
    INDIAN JOURNAL OF ANAESTHESIA, 2016, 60 (10) : 726 - 731
  • [6] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601
  • [7] Use of second generation supra-glottic airway devices during laparoscopic cholecystectomy: a prospective, randomized comparison of LMA Proseal (TM), LMA Supreme (TM) and i-gel (TM)
    Belena, J. M.
    Nunez, M.
    Vidal, A.
    Gasco, C.
    Gilsanz, C.
    Alcojor, A.
    Anta, D.
    Lopez, A. E.
    ACTA ANAESTHESIOLOGICA BELGICA, 2016, 67 (03) : 121 - 128
  • [8] Comparison of the clinical performance of airway management with the i-gel® and laryngeal mask airway Supreme™ in geriatric patients: a prospective and randomized study
    In, Chi Bum
    Cho, Sung-Ae
    Lee, Seok-Jin
    Sung, Tae-Yun
    Cho, Choon-Kyu
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2019, 72 (01) : 39 - 46
  • [9] Comparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance
    Polat, Reyhan
    Aydin, Gozde Bumin
    Ergil, Julide
    Sayin, Murat
    Kokulu, Tugba
    Ozturk, Ibrahim
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2015, 65 (05): : 343 - 348
  • [10] Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia
    Choi, Jong Bum
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Se Ryeon
    Lee, Sook Young
    Kim, Jong Yeop
    JOURNAL OF ANESTHESIA, 2016, 30 (03) : 377 - 383