RADIOLOGIC PLACEMENT OF PERITONEAL-DIALYSIS CATHETERS - PRELIMINARY EXPERIENCE

被引:39
作者
JACOBS, IG
GRAY, RR
ELLIOTT, DS
GROSMAN, H
机构
[1] WELLESLEY COLL HOSP, DEPT RADIOL, 160 WELLESLEY ST E, TORONTO M4Y 1J3, ONTARIO, CANADA
[2] OSHAWA GEN HOSP, DEPT RADIOL, OSHAWA, ONTARIO, CANADA
关键词
CATHETERS AND CATHETERIZATION; COMPLICATIONS; DIALYSIS; FLUOROSCOPY; INTERVENTIONAL PROCEDURES; PELVIC ORGANS; ABNORMALITIES; RADIOGRAPHY; PERITONITIS;
D O I
10.1148/radiology.182.1.1727292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors percutaneously placed 45 catheters for peritoneal dialysis in 32 patients, aged 31-83 years, in a radiology department. In all patients, the procedure was modified by use of the Hawkins needle, and in response to the high frequency of extrusion of the proximal cuff, the deep cuff of the 16th and each subsequent catheter was sutured to the rectus muscle or fascia. After 17 catheters were placed, the catheter was modified with a permanent bend, or "U" neck, between the two cuffs, which were then thickened. All procedures were performed with use of local anesthesia, and all catheters were successfully placed. Acute complications included bowel perforation associated with peritonitis in one patient (2%). Delayed complications included cuff extrusion in nine patients (20%), obstruction in nine patients (20%), and peritonitis requiring removal of the catheter in three patients (7%). This study shows the feasibility of percutaneous placement of peritoneal dialysis catheters by radiologists despite the need for improved technique and equipment.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 26 条
[1]   COMPLICATIONS WITH PERMANENT PERITONEAL-DIALYSIS CATHETERS - EXPERIENCE WITH 154 PERCUTANEOUSLY PLACED CATHETERS [J].
ALLON, M ;
SOUCIE, JM ;
MACON, EJ .
NEPHRON, 1988, 48 (01) :8-11
[2]  
APOSTOLIDIS NS, 1988, AM SURGEON, V54, P318
[3]   PREVENTION OF PERITONEAL-DIALYSIS CATHETER-RELATED INFECTIONS [J].
COPLEY, JB .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1987, 10 (06) :401-407
[4]  
CRONEN PW, 1985, AM SURGEON, V51, P627
[5]  
Cruz C, 1988, ASAIO Trans, V34, P941
[6]  
DALY BDT, 1980, T AM SOC ART INT ORG, V26, P444
[7]  
DIAZBUXO JA, 1984, PERITON DIALYSIS B, V4, pS100
[8]   A NEW TECHNIQUE FOR INSERTION OF THE TENCKHOFF PERITONEAL-DIALYSIS CATHETER [J].
DIPAOLO, N ;
MANGANELLI, A ;
STRAPPAVECCIA, F ;
DEMIA, M ;
GAGGIOTTI, E .
NEPHRON, 1985, 40 (04) :485-487
[9]  
FINAN PJ, 1989, ANN R COLL SURG ENGL, V61, P190
[10]   PERITONEAL ACCESS AND RELATED COMPLICATIONS IN CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS [J].
GLOOR, HJ ;
NICHOLS, WK ;
SORKIN, MI ;
PROWANT, BF ;
KENNEDY, JM ;
BAKER, B ;
NOLPH, KD .
AMERICAN JOURNAL OF MEDICINE, 1983, 74 (04) :593-598