EVALUATION OF DISSOLVED AIR FLOTATION PROCESS FOR WATER CLARIFICATION AND SLUDGE THICKENING

被引:2
|
作者
ARORA, H
DEWOLFE, JR
LEE, RG
GRUBB, TP
机构
[1] GANNETT FLEMING INC,HARRISBURG,PA 17106
[2] ILLINOIS AMER WATER CO,BELLEVILLE,IL 62223
[3] PURAC ENGN INC,WILMINGTON,DE 19808
关键词
DISSOLVED AIR FLOTATION; WATER CLARIFICATION; SLUDGE THICKENING; HIGH ALGAE CONTENT; HIGH TURBIDITY; ORGANICS REMOVAL;
D O I
10.2166/wst.1995.0524
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dissolved air flotation was evaluated using pilot and bench tests for water clarification and sludge thickening. A DAF pilot study was conducted on one water source with low turbidity, high color, high organic content and algal blooms. For this water, coagulation with alum, cationic polymer and pH around 6.1 resulted in removal of turbidity, color and algae. THMFP and TOC were removed by approximately 25 and 50 percent, respectively. A river water source was used in another pilot study to identify limits on source water turbidity for the DAF process. Tests conducted with induced high turbidity values resulted in filtered water quality with low turbidity and complete removal of color. TOC was removed by approximately 35 percent, however, inconclusive results were obtained for THMFP removal. Based on these pilot test, DAF is a viable clarification process, especially for source waters with low turbidity (infrequent spikes upto 100 NTU), high algal blooms and high color. Bench-scale DAF assisted sludge thickening resulted in performance similar to gravity thickeners. High recycle ratios (around or greater man 100 percent) were required for effective sludge thickening.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 50 条
  • [1] SLUDGE THICKENING BY DISSOLVED - AIR FLOTATION
    KATZ, WJ
    GEINOPOL.A
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1967, 39 (06): : 946 - &
  • [2] Dissolved air flotation tackles sludge thickening
    Komline, T.R.
    1600, (15):
  • [3] DISSOLVED AIR FLOTATION TACKLES SLUDGE THICKENING
    KOMLINE, TR
    WATER & WASTES ENGINEERING, 1978, 15 (02): : 63 - &
  • [4] PARAMETERS INFLUENCING SLUDGE THICKENING BY DISSOLVED AIR FLOTATION
    SUGAHARA, M
    OKU, S
    WATER SCIENCE AND TECHNOLOGY, 1993, 28 (01) : 87 - 90
  • [5] Application of dissolved air flotation to the Lenox, Massachusetts water supply; sludge thickening by flotation or lagoon
    Krofta, M.
    Wang, L.K.
    Journal of the New England Water Works Association, 1985, 99 (03) : 265 - 284
  • [6] Full-scale evaluation of activated sludge thickening by dissolved air flotation
    Haarhoff, J
    Bezuidenhout, E
    WATER SA, 1999, 25 (02) : 153 - 166
  • [7] Significance of pressure and recirculation in sludge thickening by dissolved air flotation
    Chung, TH
    Kim, DY
    WATER SCIENCE AND TECHNOLOGY, 1997, 36 (12) : 223 - 230
  • [8] USE OF DISSOLVED AIR FLOTATION FOR THICKENING OF WASTE ACTIVATED-SLUDGE
    TURNER, MT
    EFFLUENT & WATER TREATMENT JOURNAL, 1975, 15 (05): : 243 - &
  • [9] USE OF DISSOLVED AIR FLOTATION FOR THE THICKENING OF WASTE ACTIVATED SLUDGE.
    Turner, M.T.
    Effluent & Water Treatment Journal, 1975, 15 (05):
  • [10] Effect of coagulation and sonication on the dissolved air flotation (DAF) process for thickening of biological sludge in wastewater treatment
    Atamaleki, Ali
    Miranzadeh, Mohammad Bagher
    Mostafaii, Gholam Reza
    Akbari, Hosein
    Iranshahi, Leila
    Ghanbari, Farshid
    Salem, Atieh
    ENVIRONMENTAL HEALTH ENGINEERING AND MANAGEMENT JOURNAL, 2020, 7 (01): : 59 - 65