摘要
Fused silicon dioxide, multiparameter now transducers with 50 mu m internal square cross section and similar to 60 mu m length can simultaneously measure DC and RF impedance as well as fluorescence and multiple-angle Light scattering, A spherical version of such a transducer was mounted in an EPICS CVA flow-cell housing and was installed on a research prototype equipped with an argon-ion laser, The signal that was produced by the spherical transducer with EPICS DNA-Check beads was 1.73 times greater than that produced with the standard cylindrical now cell, Similarly, with EPICS Immuno-Brite beads, the average ratio was 1.96. The Coulter impedance and light-scattering measurements were similar to those produced with the conventional cylindrical outside now cell, although the internal cross section of the sphere was square and that of the cylinder was circular, The theoretical arguments of Leif and Wells have been demonstrated to be correct, At present, monolithic, spherical fused-silica transducers are the optimal design for combined electrooptical, multiparameter now cytometry analyzers. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [41] ANALYSIS OF HEAVY-METAL IMMUNOTOXICITY BY MULTIPARAMETER FLOW-CYTOMETRY - CORRELATION OF FLOW-CYTOMETRY AND IMMUNE FUNCTION DATA IN B6CF1 MICE
    BURCHIEL, SW
    HADLEY, WM
    CAMERON, CL
    FINCHER, RH
    LIM, TW
    ELIAS, L
    STEWART, CC
    INTERNATIONAL JOURNAL OF IMMUNOPHARMACOLOGY, 1987, 9 (05): : 597 - 610
  • [42] IDENTIFICATION OF A SUBPOPULATION OF REACTIVE LYMPHOCYTES IN ALLOGRAFT-REJECTION USING MULTIPARAMETER FLOW-CYTOMETRY
    TSAO, P
    RADDE, I
    WILSON, G
    COLES, J
    FASEB JOURNAL, 1991, 5 (06): : A1638 - A1638
  • [43] ASSESSMENT OF STEMLINE HETEROGENEITY IN DNA ANEUPLOID BREAST CARCINOMAS USING MULTIPARAMETER FLOW-CYTOMETRY
    VISSCHER, DW
    OTTOSEN, S
    WYKES, S
    CRISSMAN, JD
    LABORATORY INVESTIGATION, 1994, 70 (01) : A23 - A23
  • [44] ANALYSIS AND DISCRIMINATION OF NECROSIS AND APOPTOSIS (PROGRAMMED CELL-DEATH) BY MULTIPARAMETER FLOW-CYTOMETRY
    DIVE, C
    GREGORY, CD
    PHIPPS, DJ
    EVANS, DL
    MILNER, AE
    WYLLIE, AH
    BIOCHIMICA ET BIOPHYSICA ACTA, 1992, 1133 (03) : 275 - 285
  • [45] The optimisation and use of multilaser, multiparameter flow cytometers for polychromatic flow cytometry
    Dimmick, L.
    IMMUNOLOGY, 2008, 125 : 30 - 30
  • [46] RNA AND DNA CONTENT OF ISOLATED CELL-NUCLEI MEASURED BY MULTIPARAMETER FLOW-CYTOMETRY
    PIWNICKA, M
    DARZYNKIEWICZ, Z
    MELAMED, MR
    CYTOMETRY, 1983, 3 (04): : 269 - 275
  • [47] FLOW-CYTOMETRY OF SPERM
    GLEDHILL, BL
    HUMAN REPRODUCTION /: CURRENT STATUS / FUTURE PROSPECT, 1988, 768 : 363 - 369
  • [48] GENERAL-PRINCIPLES OF MULTIPARAMETER FLOW CYTOMETRIC ANALYSIS - APPLICATIONS OF FLOW-CYTOMETRY IN THE DIAGNOSTIC PATHOLOGY LABORATORY
    WILLMAN, CL
    STEWART, CC
    SEMINARS IN DIAGNOSTIC PATHOLOGY, 1989, 6 (01) : 3 - 12
  • [49] FLOW-CYTOMETRY IN LYMPHOMA
    FOUCAR, K
    WILLMAN, C
    CHEN, I
    AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1986, 10 (08) : 584 - 585
  • [50] FLOW-CYTOMETRY AND PHYTOPLANKTON
    PHINNEY, DA
    CUCCI, TL
    CYTOMETRY, 1989, 10 (05): : 511 - 521