USE OF A SPHERICAL MULTIPARAMETER TRANSDUCER FOR FLOW-CYTOMETRY

被引:3
|
作者
LEIF, RC [1 ]
CAYER, ML [1 ]
DAILEY, W [1 ]
STRIBLING, T [1 ]
GORDON, K [1 ]
机构
[1] COULTER CORP,MIAMI,FL
来源
CYTOMETRY | 1995年 / 20卷 / 02期
关键词
AUTOMATED ANALYSIS; FLUORESCENCE; COULTER; LIGHT SCATTER; AUTOMATED MULTIPARAMETER ANALYZER FOR CELLS; COMPLETE CELL ANALYSIS; CELL VOLUME; FOCUSED NOW; IMMUNOHEMATOLOGY; ELECTROOPTICAL TRANSDUCERS;
D O I
10.1002/cyto.990200212
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fused silicon dioxide, multiparameter now transducers with 50 mu m internal square cross section and similar to 60 mu m length can simultaneously measure DC and RF impedance as well as fluorescence and multiple-angle Light scattering, A spherical version of such a transducer was mounted in an EPICS CVA flow-cell housing and was installed on a research prototype equipped with an argon-ion laser, The signal that was produced by the spherical transducer with EPICS DNA-Check beads was 1.73 times greater than that produced with the standard cylindrical now cell, Similarly, with EPICS Immuno-Brite beads, the average ratio was 1.96. The Coulter impedance and light-scattering measurements were similar to those produced with the conventional cylindrical outside now cell, although the internal cross section of the sphere was square and that of the cylinder was circular, The theoretical arguments of Leif and Wells have been demonstrated to be correct, At present, monolithic, spherical fused-silica transducers are the optimal design for combined electrooptical, multiparameter now cytometry analyzers. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [31] MULTISTATION MULTIPARAMETER FLOW-CYTOMETRY - SOME INFLUENCES OF INSTRUMENTAL FACTORS ON SYSTEM PERFORMANCE
    SHAPIRO, HM
    FEINSTEIN, DM
    KIRSCH, AS
    CHRISTENSON, L
    CYTOMETRY, 1983, 4 (01): : 11 - 19
  • [32] FLOW-CYTOMETRY
    NORMAN, A
    MEDICAL PHYSICS, 1980, 7 (06) : 609 - 615
  • [33] AN ALL LEUKOCYTE WHOLE-BLOOD LYSE METHOD FOR MULTIPARAMETER FLOW-CYTOMETRY
    SERKE, S
    HUHN, D
    CLINICAL AND LABORATORY HAEMATOLOGY, 1993, 15 (04): : 275 - 285
  • [34] FLOW-CYTOMETRY
    BRAYLAN, RC
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1983, 107 (01) : 1 - 6
  • [35] FLOW-CYTOMETRY
    GILMANSACHS, A
    ANALYTICAL CHEMISTRY, 1994, 66 (13) : A700 - A707
  • [36] CHARACTERIZATION AND ENUMERATION OF SPONTANEOUSLY PROLIFERATING HUMAN-LEUKOCYTES BY MULTIPARAMETER FLOW-CYTOMETRY
    JOHANNISSON, A
    AMNEUS, H
    CELL PROLIFERATION, 1993, 26 (04) : 317 - 326
  • [37] FETAL CELLS IN THE MATERNAL CIRCULATION - ISOLATION BY MULTIPARAMETER FLOW-CYTOMETRY AND CONFIRMATION BY PCR
    WACHTEL, S
    WACHTEL, G
    PHILLIPS, O
    SHULMAN, LP
    MEYERS, C
    DOCKTER, M
    PRICE, J
    SIMPSON, JL
    ELIAS, S
    AMERICAN JOURNAL OF HUMAN GENETICS, 1991, 49 (04) : 23 - 23
  • [38] Signal transduction in chronic lymphocytic leukemia (CLL) cells by multiparameter flow-cytometry
    Palomba, M. L.
    Patel, J. P.
    Rao, U.
    Rastalsky, N.
    Lu, S. X.
    Houghton, A. N.
    Zelenetz, A. D.
    van den Brink, M. R.
    ANNALS OF ONCOLOGY, 2008, 19 : 192 - 192
  • [39] THE USE OF FLOW-CYTOMETRY IN THE STUDY OF AUTOIMMUNE NEUTROPENIA
    MACEY, MG
    SANGSTER, J
    VEYS, PA
    PROTIDES OF THE BIOLOGICAL FLUIDS, VOL 36: LIPOPROTEINS, IGG AND IGA SUBCLASSES, CYTOFLUOROMETRY, 1989, 36 : 293 - 301
  • [40] USE OF FLOW-CYTOMETRY IN ENOLOGY TO ANALYZE YEASTS
    BRUETSCHY, A
    LAURENT, M
    JACQUET, R
    LETTERS IN APPLIED MICROBIOLOGY, 1994, 18 (06) : 343 - 345