USE OF A SPHERICAL MULTIPARAMETER TRANSDUCER FOR FLOW-CYTOMETRY

被引:3
|
作者
LEIF, RC [1 ]
CAYER, ML [1 ]
DAILEY, W [1 ]
STRIBLING, T [1 ]
GORDON, K [1 ]
机构
[1] COULTER CORP,MIAMI,FL
来源
CYTOMETRY | 1995年 / 20卷 / 02期
关键词
AUTOMATED ANALYSIS; FLUORESCENCE; COULTER; LIGHT SCATTER; AUTOMATED MULTIPARAMETER ANALYZER FOR CELLS; COMPLETE CELL ANALYSIS; CELL VOLUME; FOCUSED NOW; IMMUNOHEMATOLOGY; ELECTROOPTICAL TRANSDUCERS;
D O I
10.1002/cyto.990200212
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fused silicon dioxide, multiparameter now transducers with 50 mu m internal square cross section and similar to 60 mu m length can simultaneously measure DC and RF impedance as well as fluorescence and multiple-angle Light scattering, A spherical version of such a transducer was mounted in an EPICS CVA flow-cell housing and was installed on a research prototype equipped with an argon-ion laser, The signal that was produced by the spherical transducer with EPICS DNA-Check beads was 1.73 times greater than that produced with the standard cylindrical now cell, Similarly, with EPICS Immuno-Brite beads, the average ratio was 1.96. The Coulter impedance and light-scattering measurements were similar to those produced with the conventional cylindrical outside now cell, although the internal cross section of the sphere was square and that of the cylinder was circular, The theoretical arguments of Leif and Wells have been demonstrated to be correct, At present, monolithic, spherical fused-silica transducers are the optimal design for combined electrooptical, multiparameter now cytometry analyzers. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [21] USE OF FLOW-CYTOMETRY IN CURRENT ONCOLOGY
    VERAROMAN, JM
    MEDICINA CLINICA, 1987, 88 (13): : 544 - 546
  • [22] USE OF FLOW-CYTOMETRY IN THE STUDY OF ENDOCYTOSIS
    MONSIGNY, M
    MIDOUX, P
    ROCHE, AC
    BIOLOGY OF THE CELL, 1985, 55 (1-2) : A23 - A23
  • [23] THE USE OF MULTIPARAMETER FLOW-CYTOMETRY TO ASSESS TUMOR-CELL HETEROGENEITY AND GRADE PROSTATE-CANCER
    BENSON, MC
    MCDOUGAL, DC
    COFFEY, DS
    PROSTATE, 1984, 5 (01): : 27 - 45
  • [24] FLOW-CYTOMETRY
    STEINKAMP, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (09): : 1375 - 1400
  • [25] A QUANTITATIVE-EVALUATION OF ERYTHROPOIESIS IN MYELODYSPLASTIC SYNDROMES USING MULTIPARAMETER FLOW-CYTOMETRY
    JENSEN, IM
    HOKLAND, M
    HOKLAND, P
    LEUKEMIA RESEARCH, 1993, 17 (10) : 839 - 846
  • [26] ANTIBODIES TO INTERMEDIATE FILAMENT PROTEINS AS PROBES FOR MULTIPARAMETER FLOW-CYTOMETRY OF HUMAN CANCERS
    SHANKEY, TV
    METHODS IN CELL BIOLOGY, VOL 42, 1994, 42 : 209 - 229
  • [27] FLOW-CYTOMETRY
    VANDAM, PA
    LOWE, DC
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (07): : 545 - 546
  • [28] FLOW-CYTOMETRY
    STEUTERMAN, MC
    ROSS, DW
    EMERGENCY MEDICINE, 1986, 18 (08) : 49 - &
  • [29] FLOW-CYTOMETRY
    TAYLOR, IW
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1981, 8 (04) : 409 - 410
  • [30] MULTIPARAMETER FLOW-CYTOMETRY FOR THE DETECTION AND EVALUATION OF HUMAN URINARY-BLADDER TUMORS
    FRADET, Y
    TARDIF, M
    PARENTVAUGEOIS, C
    UNION MEDICALE DU CANADA, 1985, 114 (09): : 778 - 780