X-RAY CONTRAST-MEDIA IN CORONARY ANGIOGRAPHY

被引:0
|
作者
SCHELLER, B
BACH, R
SPITZER, S
JUNG, F
SCHIEFFER, H
机构
来源
HERZ KREISLAUF | 1995年 / 27卷 / 7-8期
关键词
X-RAY CONTRAST MEDIUM; CORONARY ANGIOGRAPHY; CONTRAST MEDIUM FLOW; SIDE EFFECTS OF CONTRAST MEDIA;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In coronary angiography, the only X-ray contrast media (XRCM) employed today are iodinated and water-soluble. For invasive catheter diagnostics there are ionic and nonionic XRCM available with the requisite X-ray opacity for coronary angiography. The nonionic substances introduced in the 80s are now preferred. The decisive practical factors for XRCM are X-ray opacity and biocompatibility. The quality criterion that decides whether the X-tay contrast is sufficient is the amount of iodine administered over time, and this in turn is determined by the iodine concentration and the viscosity of the contrast medium. Tolerability of a contrast medium is governed above all by its viscosity, osmolarity and ionic concentration. This is a survey of the effect of the physical properties of XRCM on the contrast medium flow achievable and of biological tolerance with respect to side effect incidence, types of side effects as well as theological and microcirculatory effects of the substances.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 50 条
  • [1] Effect of X-ray contrast media on blood flow properties after coronary angiography
    Scheller, B
    Hennen, B
    Thünenkötter, T
    Mrowietz, C
    Markwirth, T
    Schieffer, H
    Jung, F
    THROMBOSIS RESEARCH, 1999, 96 (04) : 253 - 260
  • [2] Rotational x-ray coronary angiography
    Raman, SV
    Morford, R
    Neff, M
    Attar, TT
    Kukielka, G
    Magorien, RD
    Bush, CA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (02) : 201 - 207
  • [3] 'Gadolinium' as an alternative to lodinated contrast media for X-ray angiography in patients with severe allergy
    Ose, K
    Doue, T
    Zen, K
    Hadase, M
    Sawada, T
    Azuma, A
    Matsubara, H
    CIRCULATION JOURNAL, 2005, 69 (04) : 507 - 509
  • [4] Vessel extraction in coronary X-ray angiography
    Wang, Y.
    Toumoulin, C.
    Shu, H. Z.
    Zhou, Z. D.
    Coatrieux, J. L.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1584 - 1587
  • [5] IONIZED CALCIUM LEVELS IN CORONARY SINUS BLOOD DURING CORONARY ANGIOGRAPHY - EFFECTS OF 4 CONTRAST-MEDIA
    MITSUMORI, M
    HAYAKAWA, K
    TORIZUKA, T
    OKUNO, Y
    MONJI, T
    UWATOKO, H
    KITAMURA, K
    ABE, M
    RADIOLOGY, 1992, 183 (01) : 159 - 161
  • [6] Transfer Learning for Stenosis Detection in X-ray Coronary Angiography
    Ovalle-Magallanes, Emmanuel
    Avina-Cervantes, Juan Gabriel
    Cruz-Aceves, Ivan
    Ruiz-Pinales, Jose
    MATHEMATICS, 2020, 8 (09)
  • [7] EFFECTS OF CONTRAST-MEDIA ON THE RR AND QT INTERVAL DURING CORONARY ARTERIOGRAPHY
    MITSUMORI, M
    HAYAKAWA, K
    SOGA, T
    MAEDA, M
    TORIZUKA, T
    OKUNO, Y
    MISAKI, T
    DOKOH, S
    ACTA RADIOLOGICA, 1991, 32 (02) : 120 - 123
  • [8] Development of a rotating X-ray shutter for coronary angiography using synchrotron radiation
    Oku, Y
    Hyodo, K
    Ando, M
    Tada, J
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 123 - 127
  • [9] CARDIOVASCULAR EFFECTS OF IODINATED CONTRAST-MEDIA
    DROBINSKI, G
    MONTALESCOT, G
    SEMAINE DES HOPITAUX, 1992, 68 (11): : 306 - 309
  • [10] Decrease in Coronary Flow After Consecutive Injections of Contrast Media During Coronary Angiography
    Krepsky, Ana Maria
    Arndt, Marcelo
    Gomes, Vitor Osorio
    Caramori, Paulo
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (07): : 348 - 352